background image

7

6  Localization of light-emitting diodes (extract of the 

module)

7  Status LEDs

The module has a number of light-emitting diodes. They are used for indicating 
the status and service.

7 .1  Action

The Action diode indicates network activity. During normal operation, this 
diode lights/flashes.
Turned off: 

The module does not connect to the network. Check that the 
cable is connected correctly.

Flashing: 

Data is detected on the network. (the faster the flashing, the 
more traffic).

Steady light:  The module is connected, but there is no traffic on the network.

7 .2  Wink

The Wink diode is used for indicating the module’s conditions in three 
situations:
Start-up: 

The Wink diode is lit until a valid IP address is found. 

Localization:  The Wink diode flashes.
Service: 

By pressing the service button, the Wink diode is lit. The Wink 
diode is lit while the module is in service mode.

7 .3  Err

The Err diode is used for indicating irregularities.
Steady light:  The module has just started and is waiting for an IP address. 
Flashing: 

The module has not yet recognised the unit in which it is 
mounted (the host) 

Turned off: 

Normal situation.

Action

Wink

Error

Summary of Contents for IP201

Page 1: ...Installation instructions IP201 English Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg Tel 45 89 93 10 00 Fax 45 89 93 10 01 info kamstrup com www kamstrup com...

Page 2: ...on 4 3 Configuration 4 4 Ethernet connection 4 5 Installation 6 6 Localization of light emitting diodes extract of the module 7 7 Status LEDs 7 7 1 Action 7 7 2 Wink 7 7 3 Err 7 7 4 The service button...

Page 3: ...3 1 Mounting Typically the module is supplied mounted directly in RF Concentrator or similar equipment Example of mounting in RF Concentrator...

Page 4: ...her dynamic or static IP addresses and it is possible to order with the following settings Dynamic IP address DCHP Host server name the DNS name or IP address of the server to which the unit must repo...

Page 5: ...5 Connection to PC Terminal block No on the PCB T 568B Colour code 114 Orange White 115 Orange 117 Green 116 Green White Ethernet connection...

Page 6: ...tion to the network valid IP 3 The Err diode starts flashing when the host is recognised meter or concentrator have been detected 4 The Err diode turns off when the module has been registered by the c...

Page 7: ...raffic Steady light The module is connected but there is no traffic on the network 7 2 Wink The Wink diode is used for indicating the module s conditions in three situations Start up The Wink diode is...

Page 8: ...Kamstrup 3 wire connection that can be used for connecting additional external equipment For instance Connection of additional RF concentrator Port B is always configured for 9600 8 N 1 9 Module overv...

Reviews: