OMNIGRID Connect
Kamstrup A/S · 5512-2065_A1_GB_BSI
10/33
4.
Installation of module(s) in primary module area
Warning: Electrostatic Discharge (ESD)
Circuit board assemblies must always be handled at properly designated work areas.
Components used in electronic assemblies are sensitive to static electricity and can be damaged by
its discharge. Circuit board assemblies should be handled by the edges. Avoid touching circuits or
components.
Whenever handling a circuit board assembly, the technician must be properly grounded.
4.1
Installation of OMNIGRID Connect on top of OMNICON® 2G Modem using add-
on interface
OMNIGRID Connect is installed on top of OMNICON® 2G Modem using the add-on interface out-
lined below. It is not necessary to remove OMNICON® 2G Modem if already installed in
OMNIPOWER® meter (and supplied).
It is required to use external antenna for OMNICON® 2G Modem when used together with OM-
NIGRID Connect – remove PCB antenna and install proper external antenna (for example Kamstrup
item 6699448).
Figure 5: OMNICON 2G Modem add-on interface outlined.