Package contents:
power supply strip (1 pc.), operation manual (1pc.), rule (1 pc.).
Safety directions
Every electric work should be done by an authorized person according to regulations in force and also to recommendations of a local power station.
Before installation work switch off power supply!
Safety rules:
Before removing a cover switch off supply voltage
For cleaning power supply strip use a dry cloth.
In a case of failure absolutely cut off a whole temperature control system in a room from power supply network..
12/2009 © Copyright
KAN
Sp z o.o.
All rights reserved. Text, images and their arrangement in KAN publication are protected by proprietor’s rights.
POWER SUPPLY STRIP
OPERATION MANUAL
B2012/B4012 (without pump module)
B2022/B4022 (with pump module)
IS
O
9
0
0
1
:
2
0
0
0
Designated use and working principle
A power supply strip is used to connect temperature control devices (actuators and thermostats) in an easy, simple and handy way.
KAN
is not responsible for results of use non-conforming to its designated use.
Connecting PS strip to a power network
Technical specifications
PS strip code:
B2012/B2022
B4012/B4022
Operation voltage
230V
24V
Max. power consumption
50W
50W
Supply voltage
230V AC, 5A
230V AC, 5A
Fuse
T 4A H
T 2A H
Max. number of thermostats
6
6
Max. number of actuators
12
12
Optional heating programs
2
2
Protection class
II
II
Degree of protection
IP20
IP20
Working temperature
from 0 to 60 C
from 0 to 60°C
Storage temperature
from -25 to 60°C from -25 to 60°C
Relative humidity (no condensation)
max 80%
max 80%
Dimensions (mm)
41 / 325 / 74,5
41 / 333 / 74,5
Wieght
350g
350g
Recommended wire sections:
0,75 - 1,5 mm²
0,75 - 1,5 mm²
www.kan.com.pl