Aetos Installation Manual
3.1
Circuit Breaker
1
2
Figure 9:
Left: The power conector on cable. Right: Power connector on
Aetos back.
1
O
– hook on the power cable connector,
2
O
– notch
on Aetos back.
plastic part with a hook . . . W¨
urth Elektronik, PN 649 002 113 322,
two female crimp terminals . . . W¨
urth Elektronik, PN 649 006 137 22,
0.75 mm
2
(about AWG 18) red and blue leads.
The terminals have finitive number of mating cycles. They belong to the 25
mating cycles quality class.
3.1
Circuit Breaker
The power input must be routed trough a circuit breaker. Aetos consumes
about 800 mA at 12V on full brightness. Various peripheral devices (Daqu,
Magu, Indu, etc.) are powered via Aetos and they add to total consumption.
A rough estimate is 250 mA per device.
So a circuit breaker rated at 1.5 to 2.5 A is needed for the systems with one
Aetos. In the case of two Aetos connected to the same circuit breaker, use
2.5 to 3.5 A rated circuit breaker instead.
It is recommended that each Aetos gets its own circuit breaker.
3.2
Aircraft Master Relay
Please make sure that aircraft master relay (in fact all relays) have a protection
diode (a flyback diode)
, which protects against voltage spikes. A coil in relays
without this diode may cause spikes that exceed 100 V and they propagate
on the system bus. Such spikes may cause permanent damage on Kanardia
equipment and other avionics.