Aetos Installation Manual
10.2
Configuration
Figure 35:
Serial port configuration window.
Radio ATR833
the port is connected with an ATR 833 radio. ATR 833 spe-
cific commands will be sent to radio.
Radio Trig
the port is connected with a Trig TY91/TY92 radios. Trig’s
slightly modified SL40 protocol adapted for 8.33 kHz channel spacing
will be used for communication.
Transponder KTX2
Use this to connect to the KTX2 transponder.
This
option will transmit NMEA RMC message only. Some early KTX2
transponders were not working of other messages (like GGA) were also
present.
Flarm compatible device
the port is connected with a Power Flarm, TRX
1500, or some other Flarm compatible device. Automatic baud rate
detection is used for Flarm devices. Aetos expects one of the following
baud rates: 4800, 9600, 19200, 28800, 38400, 57600. We recommend
using higher boud rates like 38400 or 57600, when possible.
NMEA GPS out, 4800
the port will send out GPS data in NMEA format at
4800 baud, N-8-1
. RMC, GGA and GSA sentences are sent every
second.
NMEA GPS out, 9600
same as above, but at 9600 baud.
NMEA GPS out, 19200
same as above, but at 19200 baud.
CO Level sensor
Use this for Kanardia external CO sensor. Please make
sure to set the
Internal CO Sensor
option to
Not present
, see section
11.7 for more details.
5
N-8-1 – no parity, 8 bit data, one stop bit.
41
©
Kanardia
2019–2020