Aetos Installation Manual
11.3
Recorder
Figure 55:
Example of flap stops window for an airplane with three flap posi-
tions.
11.3
Recorder
In normal operation the options shall be set to
Disabled
. This means that no
special recording takes place.
Sometime, moststly due to software development purposes, a recorder may
be turned on. The record option appear on the top left area of the Modern
screen. Only one recorder can be active at the same time. The following
recorders are possible.
GDL90
can be used to record all information received from some GDL90 defice
to a USB memory stick. Such records come handy for development and
debuging TIS-B and FIS-B services of ADS-B systems.
CanData
records complete internal CAN bus traffic to USB memory stick.
Kalman
records sensors information from AD-AHRS-GPS module. It is used
for post processing, debugging and simulating AHRS behaviour.
Normally, recordings are not necessary.
11.4
Trim Sensitivity
When trim position sensors are connected and properly configured with Daqu,
Aetos can also show their position.
In order to properly detect a trim position change, an approximate travel time
from one trim stop to the opposite trim stop is required. This time will be
59
©
Kanardia
2019–2020