Aetos Installation Manual
15. Offset
For example, Aetos shows 15 feet too high regarding to reference al-
timeter. Increase correction for about 15 : 2
.
7
≈
6 steps = 0
.
6 hPa.
Dynamic (airspeed)
allows for dynamic pressure offset.
Make sure that
pito-static system is not covered/blocked and that no wind is present.
We recommend doing this in a closed hangar.
Adjust the correction, so that dynamic pressure will show zero. We
recommend doing this at least once per year – say at the start of every
season.
Engine total time
changes the engine total time counter to a new value.
This comes handy when there is a difference between engine total time
in aircraft books and Aetos logs. The engine total time change is visible
from the logs. The change will not correct the existing logs. It will only
affect new ones. It takes about 10 seconds for the change to become
permanent. Do not close/reboot Nesis for 10 seconds after the change.
Flight total time
changes the flight total time counter to a new value.
The change will not correct the existing logs. It will only affect new
ones. It takes about 10 seconds for the change to become permanent.
Do not close/reboot Nesis for 10 seconds after the change.
Fuel flow factor
affects software based fuel factor only. It does not affect
sensor fuel flow factor. It is used to correct fuel flow indication for
the cases where fuel flow is computed from engine RPM and manifold
pressure for a known engine. Increasing the factor will also increase the
calculated fuel consumption.
Use software based fuel flow with great care. The indications may be
incorrect and this indication will also impact the software based fuel
tank, range and endurance, when used. Never trust the software based
fuel flow and software based fuel level. Make sure that you have some
reliable way to check the actual fuel level during the flight.
Carbon monoxide
allows for the CO sensor offset. Note that some Aetos
models do not have CO sensor installed. With the engine turned off
and in a good ventilated area with a cabin opened, adjust the CO
indication so that it will show about 0 ppm. Note that some populated
and polluted surroundings may have significant amount of CO in the
air. Normal values in clean environment are up to 2 ppm.
77
©
Kanardia
2019–2020