Aetos Installation Manual
14.1
Fuel Level Sensors
Figure 66:
An example of linear fuel tank.
Figure 67:
An example of linear fuel tank.
14.1.2
User Shape
This is the most complex solution, but also the most precise one. It allows
up to 20 calibration points per tank. 20 points are an overkill, 5-8 points
are usually more than enough. Fuel level sensors precision and resolution
are quite limited and sometimes also fuel type dependent. Having too much
points in calibration is not beneficial.
In order to define a user shape for tank, set the
Shape
parameter to
User
.
The window will change slightly. Then select the
Edit
item. This opens a
window, where tank measurements are manipulated.
A typical procedure is described next. Taking notes on paper about every
measurement point is highly recommended.
1. Make sure that aircraft is in level position for a cruise flight.
2. Make the tank empty – drain all fuel out. Select proper fuel sensor (or
tank) and set
User
shape. Select the
Edit
item and issue the
Clear
com-
mand to remove any existing points. Figure 68a shows the situation.
72
©
Kanardia
2019–2020