Emsis — Manual
5.4
Emsis Setup Screen
D: Same as B, but it also allow you to connect sensors that
generate 4-20 mA current loop (one typical sensor is Rotax oil
pressure sensor).
E: Same as B, but it also allows measuring resistance with
stronger current generator. It is typically used for fuel level
probes.).
Z: digital channel for engine RPM. It measures time between
pulses. Z channel has special “normalizing” electronics, which
is capable to measure signals from a wide voltage range. (Rotax
100-200 V range and Jabuiru 0.5V range.
Y: digital channels, used to measure time between pulses.
Pulses are expected to have a proper shape.
Please refer to Daqu Manual for more details.
After sensors are connected to the Daqu unit, each sensor needs to be
configured. Select each channel from the list by using
up
and
down
buttons and confirm selection by pushing the
OK
button. Window
illustrated in Figure 15 opens.
To change the specifications, follow the next procedure:
1. with
up
and
down
buttons select item you want to change and
press the
OK
button,
2. select the value using
up
and
down
buttons and press the
OK
button to confirm,
3. press the
close
button to close the window, changes are saved
automatically.
37
©
Kanardia