Emsis — Manual
2.6
CAN Bus
Description
Value
Weight
80 PFD: 298 g
80 EMS: 230 g
Size
80 PFD: 82 x 82 x 65 mm
80 EMS: 82 x 82 x 45 mm
Operational voltage
6 V to 32 V
Current
150 mA (PFD) or 140 mA (EMS) at 12 V
85 mA at 24 V
Operating temperature
-30
∼
+85
◦
C
Humidity
30
∼
90 %, non condensing
Panel hole
80 mm (3.15 inch) diameter, standard fit
Altitude range
-500 m to 16000 m (-1600 to 52000 feet)
Acceleration
16 bit, 3D, dynamic range 0 to 16 g,
typical resolution 0.12 mg
Angular rate
16 bit, 3D, 250
◦
/s, resolution 0.009
◦
/s
Barometric sensor
24 bit, 10 to 1200 hPa, 20 cm resolution
Airspeed sensor
12 bit, 0 to 69 hPa, 381 km/h, 205 kt
resolution
<
0.1 km/h
(units before Oct 19)
0 to 50 hPa, 325 km/h, 175 kt
GPS
10 Hz, 66 channel, hot start 1 s, cold 35 s,
sensitivity -165 dBm
OAT
12 bit, range -55
°
C to 125
°
C,
0.5
°
C accuracy
QNH range
590 hPa to 1080 hPa
(17.42 to 31.89 inHg)
Communication
CAN bus, 29 bit header, 500 kbit,
Kanardia protocol
Display
240 x 320 pix, 2.7”, 24 bit,
full colour, super bright
Table 1:
Basic technical specifications for the 80 mm Emsis.
16
©
Kanardia
2021