Emsis — Manual
5.4
Emsis Setup Screen
Figure 21:
Window for setting Emsis layout
push the
close
button to save and exit the window. Emsis will
restart.
AHRS Level
During the assembly of the AHRS unit into the Em-
sis unit and during the installation of the Emsis unit into the in-
strument panel, a small misalignment may appear. This means that
internal axes of the AHRS unit are not parallel to the airplane axes
– the AHRS unit is slightly rotated. Such misalignment can be per-
fectly adjusted without loss of precision using the procedure described
next.
Please make sure that airplane is level for both, roll and pitch. Make
also sure that Emsis unit is turned ON for at least five minutes – this
warms up the internal electronics and stabilizes numerical filters.
Once the airplane is level and steady, select the AHRS level option
to start the automatic calibration procedure. Window illustrated in
Figure 22 opens.
Figure 22:
Calibrating the AHRS level
45
©
Kanardia