Emsis — Manual
7.2
Hardware Tank
its max point) way before the tank is completely full. Stop at
the point where sensor do not react anymore.
13. Close the
Edit tank
window pressing the
close
button. Now
you are back to the
Tank
window. This window shows your
tank curve. Name of the curve will be
Custom
. Press
close
again to close the
Tank
window and save the new shape – only
now the new shape is really saved.
Hint: While editing a number, you can use the
screen selector
button to delete the highlighted character.
IMPORTANT: Once you have your shape defined and you see
Custom
next to the shape label in the
Tank
window,
do not
play and change the shape to anything else. If you do, you will
lose your calibration without a warning and you will have to
enter it once again.
It is important to take notes for each measuring point. Figure 35
shows an example. In the case that something went wrong and the
tank calibration is not stored correctly, you can restore it from the
notes – there is no need to drain the tank again and mess with the
fuel.
1. Select
T1 Shape
from the
Tank
option in order to open the
tank calibration window.
2. Press and hold the
OK
button – this opens
Edit Tank
window.
3. The window may show a few measuring points (volume – sen-
sor pairs). Check if they match with the notes (some minor
difference is OK).