Emsis — Manual
7.2
Hardware Tank
position differences. It gives good results, when sensor behaviour
is predictable (read relay based sensors, for example) or in serial
production, when sensor are installed with high precision.
This procedure requires two steps. In the first step, the tank shape
is selected and in the second step, sensor value for empty (min) and
full (max) condition is given.
1. Select the
Tank
option from the main menu. This offers further
selection according to the Figure 32.
2. Select
T1 Shape
.
This opens a tank shape window, Figure
36. Use
up
or
down
button to select the correct shape for your
aircraft tank. The graphics below shows the non-linearity of the
tank. Straight diagonal line indicates that the tank is linear.
Please note that changing the shape deletes any existing tank
calibration. See the
IMPORTANT
box on the page 65.
Figure 36:
Tank shape selection window. The figure shows that the
curve for the Dynamic WT9 tank is very non-linear
67
©