Page 6 of 21

2.3

Required signal processor

The following information does not apply to the option "XO" :
When using the SONA SUB II, a signal processor is required such as an electronic crossover or
the K&F Controller CD 44.

The signal processor must provide at least the following settings:

1 x high-pass 4th order

1 x low-pass 4th order

1 x bell filter

Further information in chapter Configuration and Connecting Diagram on page 10 ff.

3.

Safety Instructions

3.1

Mounting the Speakers / Wall and Ceiling Installation

Warning

Suspended loads pose a safety risk.

Only qualified technicians are permitted to perform the installation steps. Be sure to use
personal protective equipment at all times.

The technicians installing the speaker on site are responsible for and guarantee safe setup
and use.

Never use signal cables or power cords for suspending, aligning, or securing the systems.

Before installing, check the stability, strength, and materials of walls, ceilings, and boarding.
For example, use suitable rawlplugs for wall panels and make sure the strength is sufficient.

Note that the suspension points on the hall ceiling (i.e. shackles, attachment points, or chain
hoists) must comply with the DGUV regulations 17 or similar locally applicable accident-
control standards. The maximum load must have been certified by an authorized expert.

Be sure to tighten all bolts and screws to the specified torque.

Unless otherwise stated, use only KLING & FREITAG original parts for mounting the speakers.
Never use other parts (in particular, parts not made by KLING & FREITAG).

Make sure all fittings used are suitable for the task at hand and meet all relevant safety
requirements.

Ensure that all connections are secured against coming loose and that only authorized,
statically tested and correctly sized supports, mounting equipment, wire ropes and chains are
used.

Be sure to always visually inspect all safety-related speaker and accessory components
before use. If there are signs of wear, cracks, or deformation, etc., replace the affected parts
immediately. Visual inspection also includes checking all screwed connections of supporting
components.

The information described here does not relieve the user of the duty to follow the given
safety requirements and legal regulations.

3.2

Notes for Mounting the Speakers

Warning

Mount the speakers securely. To avoid injury or damage, always be sure to mount the
speakers securely so that they do not fall.

Please note that speakers can move as a result of vibrations. To prevent them from falling
from their mounted position, they must be secured properly.

Run the cables in a way that nobody can trip over them.

Summary of Contents for SONA SUB II

Page 1: ...Please Read Before Use KLING FREITAG GmbH Junkersstra e 14 D 30179 Hannover TEL 49 0 511 96 99 70 FAX 49 0 511 67 37 94 www kling freitag de Operating Instructions Translation of the original instruc...

Page 2: ......

Page 3: ...ng Damage 6 3 4 Protecting the Speakers Operating Safety 7 4 Correct Ratio between Top and Subwoofer 9 4 1 Level increase because of adjacent areas 9 5 Configuration and Connecting Diagram 10 5 1 Term...

Page 4: ...damage Tip This icon marks information provided for simplified use of the described products 1 2 About these operating instructions KLING FREITAG GMBH All rights reserved All specifications regarding...

Page 5: ...ted with a universal electronic crossover This possibility makes it extremely attractive not only because of its convincing performance but also economically SONA Lautsprecherserie 2 1 Items Included...

Page 6: ...with the DGUV regulations 17 or similar locally applicable accident control standards The maximum load must have been certified by an authorized expert Be sure to tighten all bolts and screws to the s...

Page 7: ...e clipping limiters Alternately you can also insert a clipping limiter before the amplifier To achieve sensible acoustic results and to protect the speaker from mechanical destruction during use the s...

Page 8: ...ers magnetic fields Speakers are permanently surrounded by a magnetic field even when they are not connected Therefore during transport and placement of the speakers it is important to ensure that the...

Page 9: ...elect use with the CD 44 For an additional bass boost the level increase which occurs in room edges and room corners can be used The placement in room edges and room corners is also beneficial because...

Page 10: ...Version 1 5 Page 10 of 21 5 Configuration and Connecting Diagram 5 1 Terminal assignment In 1 In 2 Without the option XO the second phoenix output is parallel to the first phoenix output At the XO op...

Page 11: ...and systemrack connection diagram K F SystemRack MONO MIX STEREO SONA SUB II SONA 6 SONA 6 STEREO SONA 5 SONA 5 SONA 5 SONA 5 STEREO SONA 8 MONO CD 44 Settings SONA 6 In the CD 44 choose the LSBlock S...

Page 12: ...r Amplifier SONA SUB II Amplifier Signal Processor SONA 6 SONA 6 STEREO SONA 5 SONA 5 SONA 5 SONA 5 STEREO SONA 8 MONO Signal processor settings SONA SUB II High pass 32 Hz 4th order Butterworth 1 x l...

Page 13: ...rsion 1 5 Page 13 of 21 5 4 SONA SUB II XO with SONA top connection SONA 5 or SONA 6 STEREO SONA SUB II Amplifier Option XO STEREO STEREO SONA 6 SONA 6 SONA 5 SONA 5 SONA 5 SONA 5 STEREO STEREO connec...

Page 14: ...e wire gauge depends on the length of the speaker cable Minimum Wire Gauge mm Required Cable Length m 2 x Speaker Impedance Ohm For connections to the power amplifier inputs please use 2 pin shielded...

Page 15: ...rd through those speakers Turning down the input level controls may not always prevent distortions in the input section of the power amplifier especially if this section has a relatively low headroom...

Page 16: ...20 dB SPL half space Components 2 x 8 woofer with 50 mm voice coil Impedance nominal 2 x 8 Ohm Stereo 4 Ohm Mono Connection 2 x 4 Pol phoenix connector and speakon NL4MPR parallel Enclosure Design 12...

Page 17: ...ONA SUB II KLING FREITAG GMBH 2016 Version 1 5 Page 17 of 21 9 Measuring Diagrams 0 0 1 0 2 1000 70 80 90 100 Frequency response Frequency response Option XO Frequency Hz SPL dB 0 10 20 30 40 50 60 70...

Page 18: ...Operating Instructions K F SONA SUB II KLING FREITAG GMBH 2016 Version 1 5 Page 18 of 21 10 Dimensions Weight 16 9 kg 536 0 mm 21 102 308 0 mm 12 126 485 0 mm 19 094 485 0 mm 19 094...

Page 19: ...crossed out garbage can with a white bar below it The icon indicates that the equipment was distributed on or after 24 March 2006 and must not be disposed of through household waste KLING FREITAG Gmb...

Page 20: ...5 SONA 6 SONA 8 SONA SUB SONS SUB II SW 112 SW 115D SW 115E SW 118E SW 212E These products are discontinued These systems are not covered by the Low Voltage Directive because of the rated voltage used...

Page 21: ...Operating Instructions K F SONA SUB II KLING FREITAG GMBH 2016 Version 1 5 Page 21 of 21 Managing Director CEO...

Reviews: