22
II.
Segmentation
:
double amplitude modes, Amplitude Segment/Stage A and
Segment/Stage B and the proportion of Segment A can be displayed.
Setting scope:
Segment A: same as Fixed mode;
Segment B: 10-100%
;
Stage A proportion: 10-100%.
Note
:
Segment B proportion will not be displayed, because Segment B proportion is
“
100%-Segment A proportion
“
Trigger mode:
Same as Trigger Preparation page.
Run mode:
Ⅰ
.Time: Weld time 0-10S
;
Ⅱ
.Energy: Weld energy 0-6000J
;
Ⅲ
.Time+Energy
;
IV. GND (External), 0-10s.
Hold time
:
0-10S after welding.
Shake-off amplitude
:
After cooling, the secondary ultrasonic vibration amplitude is
10-100%
。
Shake-off delay
:
Secondary ultrasonic vibration delay time is 1-10S.
Shake-off time
:
Secondary ultrasonic vibration time is 1-10S, when it is set at 0S,
secondary ultrasonic vibration is stopped.