19
4. Support leg
5. Casters
6. Damper
12. INVERTER GENERATOR SPECIFICATIONS
Model
KS 1200i
KS 2100i
Voltage, V
230
230
Maximum power, kW
1.2
1.8
Nominal power, kW
1.0
1.6
Power factor, cos φ
1
1
Current, A (max.)
5.22
7.83
Frequency, Hz
50
50
Outlets
1х16А (230V)
2х16А (230V)
Engine start
Manual
Manual
Fuel tank volume, L
3.5
5.5
Operating time at 50% load, h
5.5
4.5
Noise level Lpa/Lwa, dB
67 / 92
68 / 93
LCD display
-
-
Output 12V, A
5.0
8.3
Engine model
KS 110i
KS 140i
Engine power, hp
2.0
3.26
Crankcase volume, cm
3
0.4
0.4
Engine volume, cm
3
87
119
Engine type
Gasoline powered one-cylinder,
four-stroke air-cooled
Power output controller
АVR
Mobile control
-
-
Gas operation
-
-
Net dimensions (L*W*H), mm
310*310*380
375*340*405
Gross dimensions (L*W*H), mm
335*330*415
410*380*435
Battery, Ah
-
-
Net weight, kg
13
18
Protection class
IP23M
Nominal voltage tolerance - max. 5%
To ensure reliability and increase the engine service life, peak powers may be slightly
limited by circuit breakers.
The optimal operating conditions are ambient temperature of 17-25°C, barometric
pressure of 0.1 MPa (760 mm Hg), and relative humidity of 50-60%. Under these
environmental conditions, the generator can provide maximum performance in terms
of the declared specifications.
In the event of deviations from these environmental indicators, the generator
performance may vary.
Please note that in order to preserve the long service life of the generator, continuous
loads of more than 80% of the nominal power are not recommended.