23
13. FUNCTIONAL DESCRIPTION OF
INVERTER GENERATORS
PARALLEL FUNCTION
The total output power of the generators can be increased by connecting two
inverter generators together using the Parallel Unit.
Parallel connection of two identical generator models ensures double nominal
output power of these models.
When connecting generators of different capacities using the Parallel function,
the output power is two times the nominal power of the generator with lesser
capacity.
The total output power of the generators can be increased by connecting two
inverter generators together using the Parallel Unit.
Parallel connection of two identical generator models ensures double nominal
output power of these models.
When connecting generators of different capacities using the Parallel function,
the output power is two times the nominal power of the generator with lesser
capacity.
Parallel el Unit
Fig. 19
1. Start the engine.
2. Set the ECON switch to “ON”.
3. Plug the device into an AC outlet.
4. Make sure the AC indicator light is on.
5. Turn on the electrical device.
The ECON switch must be set to “OFF” to increase engine speed
to nominal. When connecting multiple power consumers to the
generator, be sure to first connect the one with the highest starting
current, and the device with the lowest starting current should be
connected last.
!
!
PLEASE NOTE!
ECON FUNCTION ECON FUNCTION