24
TURBO FUNCTION
The ECON switch must be set back to “OFF” when using electrical
devices requiring a high starting current, such as a compressor or
submersible pump.
!
!
PLEASE NOTE!
“ON” MODE
When the ECON switch is in the “ON” position, the
control unit monitors the engine speed, reducing
it commensurate with the connected load. If
the engine speed is not enough to generate
electricity to provide the load, the control unit will
automatically increase the engine speed.
As a result, fuel consumption is optimized and
noise levels are reduced.
Fig. 20
“OFF” MODE
The ECON switch must be set back to “OFF” when using electrical devices
requiring a high starting current, such as a compressor or submersible pump.
Generator models KS 3300iEG S-Profi, KS 3500iE G-Profi, KS 4000iEG S-Profi,
KS 7100iE G-Profi, KS 7200iEG S-Profi feature a TURBO mode, which allows to
start up power consumers that require more starting power, than the generator
can produce in normal operation.
Use the ECONOMY MODE switch to change the operating mode of the generator
from “TURBO” to “ECON” and vice versa.
When the ECONOMY MODE switch is set to “OFF”, the TURBO function is turned
on for 60 seconds to enable equipment that requires more power to start up.
After 60 seconds, the TURBO function will turn off and the generator will
automatically return to normal operation. In the TURBO mode, the generator
power increases by 20%.
To enable the ECON mode, set the ECONOMY MODE switch to “ON”.
Generator models KS 3300iEG S-Profi, KS 3500iE G-Profi, KS 4000iEG S-Profi,
KS 7100iE G-Profi, KS 7200iEG S-Profi feature a TURBO mode, which allows to
start up power consumers that require more starting power, than the generator
can produce in normal operation.
Use the ECONOMY MODE switch to change the operating mode of the generator
from “TURBO” to “ECON” and vice versa.
When the ECONOMY MODE switch is set to “OFF”, the TURBO function is turned
on for 60 seconds to enable equipment that requires more power to start up.
After 60 seconds, the TURBO function will turn off and the generator will
automatically return to normal operation. In the TURBO mode, the generator
power increases by 20%. To enable the ECON mode, set the ECONOMY MODE
switch to “ON”.