40
28. TROUBLESHOOTING
Fault
Probable cause
Remedy
Engine will not start
Engine switch set to OFF
Set the engine switch to ON
Fuel tank is empty
Add fuel
Engine contains dirty or old fuel
Replace fuel in the engine
Low oil level
Add fresh oil to the specified
level
Reduced engine power /
troubled engine start
Fuel tank is dirty
Clean the fuel tank
Air filter is dirty
Replace the air filter
Water or air in the fuel line
Bleed the fuel line
Engine overheating
Cooling fins are contaminated
Clean the cooling fins
Air filter is dirty
Replace the air filter
Engine starts, but no
output voltage
Circuit breaker tripped
Set the circuit breaker to ON
or shut off and then start the
generator again
Connection cables of poor
quality
Check cables for normal
operation; replace, if extension
cable is used
Faulty connected device
Try connecting another device
Generator works, but does
not support connected
electrical devices
Device overload
Try connecting fewer devices
Short circuit of one of the
connected devices
Try disconnecting the faulty
device
Insufficient engine speed
Contact the service center
Summary of Contents for KS 1200i