18
STARTING THE GENERATOR
- Do not connect any power consumers to the generator before the engine start.
- Connect the terminals to the battery and pay attention to the correct polarity
(plus/+ to plus/+, minus/- to minus/-).
- Set the ignition key to ON.
- Turn the key clockwise to the START position.
- After a successful start, release the key and it will automatically return to the
ON position.
- If the engine doesn’t start after pressing and holding down the key in the
START position for 5 seconds, wait 15 seconds before the next attempt to start.
Lengthy operation of the engine start system may discharge the battery. While
the generator is running, leave the key in the ON position.
- After three minutes of the generator operation, switch the circuit breaker
(circuit breaker Fig. no. 4) to the upper position (ON).
Before connecting devices to the generator, make sure that they are in good
condition. If the device that was connected suddenly stopped or failed,
immediately disconnect the power using a circuit breaker (Fig. 3, no. 4),
disconnect the device and check it.
Do not connect of two or more devices simultaneously.
The start-up of many devices requires high power.
Devices should be connected in turn according to their power rating.
Do not connect any power consumers within the first 3 minutes
after the generator start.
If the engine does not start after three or four attempts, this may
mean that air has entered the fuel system. Remove air from the fuel
system (drain diesel fuel together with excess air).
IMPORTANT!
ATTENTION - DANGER!