To pin-point a gas leak: 

 

After completing the warm up period in 

fresh air,

 move the tip of the 

GLD/450plus’s “wand” towards the suspected gas leak.  The rate of 
bleeping and LED flashing will increase as the concentration of the gas 
increases, thereby leading you to the gas leak. 

 

If the Red LED is illuminated and the bleeping is continuous before you 
have pin-pointed the gas leak, you must reset the GLD/450plus in this 
concentration of gas.  To do this switch the GLD/450plus OFF, then back 
ON and wait for 20 seconds to allow the sensor to reset itself in this 
concentration of gas.  You can then continue to pin-point the gas leak. 

 

Tips: 

 

If the initial bleep rate does not settle to about twice a second, switch off 
and back on to allow additional re-setting time. 

 

The unit may be reset at any time by switching off and back on. 

 

The unit will detect methane and most other "HC" gases down to low 
ppm levels. 

 

The unit will respond to some leak detection fluids.  Use the 
GLD/450plus first! 

 

The unit is intended for use in sheltered areas or indoors as severe 
draughts may cause (temporary) false indication. 

 

Avoid contamination by water or dirt and do not allow any reactive 
chemicals etc. to come in to contact with the sensor. 
 

ELECTROMAGNETIC  

COMPATIBILITY 

 

 

 

This product has been 
tested for compliance with 
the following generic 
standards: 

 

EN61000-6-3 
EN61000-6-1 

 

 

and is certified to be compliant 

 

Specification EC/EMC/KI/GLD/450PLUS/001 

details the specific test configuration, 

performance and conditions of use.

 

PROTECTION 

AGAINST ELECTRIC 

SHOCK 

 

(in accordance with 

 EN 61010-1 : 1993) 

This instrument is 

designated as Class 3, 

SELV. 

 

 

 