11
PAGE
Repair Instructions
K 350
Assembling the
electrical parts
1
Connect all cables to the switch (see illus-
tration and wiring diagram).
2
Push the field cables (18,19) through the
handle (see illustration).
3
Insert the switch (22), the capacitor (24).
Note: Install the field supply cables (A)
below the mains cable near the cable col-
lar (17).
4
Fasten the cable collar (17) with
screws (85) (1Nm).
Mounting the
handle
1
Screw (10 Nm) the handle bolt (68) with
screw locking device onto the motor hous-
ing (27).
2
Push the handle (86) over the bolt (68)
and fix the AVS-rubber (87) with the wash-
er (5) and locking ring (6).
3
Insert the silicone buffer (87) into the han-
dle cover (86).
4
Fasten the handle cover (86) with the
bolts (85) (1,2 Nm).
5
Push the field supply cables (18,19)
through the channels of the field housing
(see illustration) and connect them with
the field (diagonally).
6
Fasten the handle with the grooved dowel
pin (4).
Press in the grooved dowel pin (4) or
knock it in with a rubber hammer.
Mounting the
motor cover
1
Fit the protective cap (8) and fasten it with
the bolts (85) (1,8 Nm).
☞
Take care that the protective cap (87)
is firmly stuck in the motor cover (8).