4.9 Baby Tray  

The Baby Tray may be fixed to the Bed Platform or be loose, depending on your order.  
Having the Bed Tray loose allows you to lift it out for easy cleaning and for cleaning of the 
Bed Platform as well.  
In case you want the Baby Tray permanently fixed to the Bed Platform Kanmed can supply a 
special tape for this purpose. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4.10

 

Storage Boxes 

Storage Boxes with or without lid can be  
mounted under the Bed Platform.  
They can be swung around for easy access.  
Swing them back in after use. 
Respect the load limits written on the 
Lid and in the Storage Boxes 

 
 
 
 
 

 
 

4.11 Kanmed BabyWarmer  

The Kanmed BabyWarmer Control Unit can be hung on  
the Side Rails. A special handle (800-0057) can replace  
the existing handle and will reduce  
the risk of the unit accidentally falling of the rail.  
See www.kanmed.se or contact your distributor. 
The Heating Pad cable is preferably thread through  
one of the holes in the Bed Tray  
before connecting to the Control Unit.  
 

Summary of Contents for BABYBED BB100

Page 1: ...istributed by This manual is valid for all BabyBeds that has the Red Stoppers in the side walls and also valid for beds that has been upgraded to hydraulic tilt release and or new side walls with Red Stoppers Caution Please read this manual carefully Incorrect use may cause patient or user injury ...

Page 2: ...NSTRUCTIONS FOR USE 5 5 CLEANING 10 6 REGULAR SAFETY CHECKS BEFORE USE 13 7 TROUBLE SHOOTING 13 8 TECHNICAL DATA 14 9 TECHNICAL SECTION SERVICE AND MAINTENANCE 15 10 SPARE PARTS ACCESSORIES 17 11 WARRANTY STATEMENT 18 12 EMC GUIDE LINES 18 13 DISPOSAL 18 BB101Standard without rails BB100 Standard with rails BB400 Twin Version with rails ...

Page 3: ...osition when the baby is unattended Do not move the Bed around in the high position Always use the lowest position Do not use the Side Walls to move the Bed always use depending of model the Side Rails or front handle Do not leave a baby unattended with the Side Walls down Respect the weight limits Check that the Bed is not wobbly meaning that all wheels and bolts are tightened Ensure that there a...

Page 4: ... around the Bed Max 3 5 kg on each Rail Max totally 10 kg on all Rails Shelf 5kg Rear mount kit poles 3 kg each Front handle 5 kg models without side rails Symbol on Foot Pedal for raising and lowering the Bed Platform not for BB300 and BB400F Symbol for tilt function found on the Bed Tray Label Fulfils MDD 93 42 EEC Earth potential equalization connection point IP 30 Degree of protection against ...

Page 5: ...dges Pull straight up 5mm inch pull towards you 2 cm 1 inch push down gently Use both hands to pull the Side Walls up again push a little forward and then lower it Ensure that they are securely in place Ensure that all Side Walls are moving correctly and in good condition NOTE Check that nothing gets trapped when you lower and raise the Side Walls NOTE Removing the Side Walls see section 5 Cleanin...

Page 6: ...and BB400F 401F The height is adjustable by pressing the Foot Pedal at the wheel base Connect power and run the Bed up and down and ensure that it moves smoothly without any unusual noise The motor can be heard which is an indication warning that the Bed Platform is now moving Foot pedals can be mounted on the left or right side or on both sides Front pedal is also available WARNING When changing ...

Page 7: ...rt no BB173 4 8 Tent Pole Tent and Mattress Mount the Tent Pole in the rear bracket Turn it to a 90 degree angle from the Bed and press it down so the screws can pass in the groves The Tent has a channel inside Thread the Tent Pole into the channel in order to secure it and place the Tent sides on the outside of the Side Walls Place the Mattress in the Bed Other mattress types and homemade tents m...

Page 8: ...torage Boxes with or without lid can be mounted under the Bed Platform They can be swung around for easy access Swing them back in after use Respect the load limits written on the Lid and in the Storage Boxes 4 11 Kanmed BabyWarmer The Kanmed BabyWarmer Control Unit can be hung on the Side Rails A special handle 800 0057 can replace the existing handle and will reduce the risk of the unit accident...

Page 9: ... information about the use of the Kanmed BabyWarmer 4 12 2 Rear mount Kit All beds can be equipped with a rear mount kit that will hold the Baby Warmer Control Unit securely Tubes are standard 25 diameter stainless steel tubes Ordering numbers are found in Section 10 Max weight on each pole 3 kg 4 12 3 Optional shelf A shelf can be ordered instead of the Storage Boxes Art no 800 0530 4 12 4 Change...

Page 10: ...Disinfection The Kanmed BabyBed withstands most common surface disinfectants used in hospitals Disinfectant wipes with Virkon Diversey Limpiador Clorado Clinell wipes Chlor Clean wipes Meliseptol rapid Dax yt Terralin Dsimozon pur perform and similar If in doubt try on a small surface or contact your distributor or Kanmed SPECIFIC INFORMATION 5 1 Cleaning of the Bed Use well wrung out cloths NOTE ...

Page 11: ...d 5 5 Putting Side Walls back in place 5 5 1 Beds with Side Wall Guides Insert the side wall guides in the corners Observe L left and R right Place them as in the picture Press the pin on the guide firmly into the hole in the corner Insert the Side Wall in the groves see arrow and slide them down The folded upper edge of the side wall shall face outwards Side walls will easily slide click in place...

Page 12: ...es and Lids are cleaned and disinfected same way as the rest of the Bed 5 7 Mattress Use a surface cleaning and disinfecting agents recommended by Kanmed above 5 8 Tent See label for washing instructions In case of contamination the Tent may be washed at 90 C but this may result in shrinking and an earlier wear out 5 9 Side wall Corner If your side wall corner do not have the small hook as indicat...

Page 13: ...ser See Kanmed BabyWarmer user manual Wheels brakes User Before every use 7 Trouble shooting Symptom Possible cause Action The lifting column does not move as wanted not for BB300 301 and BB400F 401F No mains Check the cables Check power outlet Something obstructing the movement Check that nothing blocks Electrical connection broken or not properly connected Technical service Foot Pedal faulty or ...

Page 14: ...ltage BB100 400 230V 50Hz 60Hz or 115V 60Hz 150VA Fuses BB100 400 2xT6 3A 230V Only replace with same type and rating Power outlet on Pillar BB100 101 and BB400 401 Max 300W Protection BB100 101 400 401 Class I Products is CE marked Conforms to UL 60601 1 Environmental data In use 10 to 40ºC 85 RH Transport 20 to 60ºC non condensing Storage 10 to 40ºC non condensing Atmospheric pressure 70 to 106 ...

Page 15: ...at they roll without noise and that the wheel locking function works properly Check that all screws are properly tightened especially the screws connecting the height adjusting Pillar to the wheel base the screws on top of the Pillar the screws holding the Bed Platform and Gas Spring Check that Foot Pedal Label is not worn Check that the Bed Tray Labels are not worn Service NOTE Always unplug the ...

Page 16: ... to fit New stripes can be ordered at Kanmed 9 5 Changing the Foot Pedal electrical connections Lay the Bed carefully on its side Unplug the pedal from the Pillar Unscrew the Foot Pedal and replace it Raise the Bed and check functions and that up down arrows are indicating correct 9 5 1 Adding an extra foot pedal or front foot pedal Please contact kanmed for necessary instructions and parts 9 6 Ch...

Page 17: ...073 Side Wall Guide Right side Set of 4 800 0072 Red side wall stopper Set of 4 800 0023 Side Rail front rear BB100 BB300 Length 40cm 800 0022 Side Rail sides BB100 BB300 Length 62 cm 800 0044 Side Rail front rear BB400 BB400F Length 57 7 cm 800 0045 Side Rail sides BB400 BB400F Length 72 3 cm 800 0011 Corner handle for Side Rail beds With side wall guides 800 0110 Corner handle BB100 400 May 2017...

Page 18: ...abyBed fulfils the applicable requirements of IEC 60601 1 2 2007 Electromagnetic compatibility EMC The BabyBed shall be used in a hospital environment but not close to HF surgical equipment or MR cameras WARNING Use of accessories and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic ...

Page 19: ...User Manual BB100 400 070 Page 19 of 20 ...

Page 20: ...nual BB100 400 070 Page 20 of 20 Kanmed AB Gårdsfogdevägen 18B SE 168 67 BROMMA Stockholm Sweden Telephone 46 8 56 48 06 30 Telefax 46 8 56 48 06 39 E Mail info kanmed se Web page www kanmed se Distributed by ...

Reviews: