13.2. Battery pack reassembly
(1) Replace the O-ring (d) of the housing then connect the 3 male connectors (c) of the new
battery pack to the 3 female connectors of the connectors harness (b).
CAUTION: to avoid reversal of polarity, the male connectors are fitted with a locking
strap (e) and the female connectors are fitted with a positioning lug (f); lift the locking
straps (e) of each male connector (c) and fix them to the positioning lugs (f) of each
female connector.
(2) Connect the connectors harness (b) to the white connector (a) located in the bottom of the
housing.
(3) Insert the battery pack into the housing of the beacon taking care not to pinch the wires.
CAUTION: the wires must be positioned on the opposite side of the white connector (a).
(4) Reassemble and screw the housing of the battery pack.(5)Note the new expiration date (date
of repla 6 years) in the field «Lithium battery Expiration date» located on the beacon.