Chapter 9    Warranty and After-sales Services 

 

The limited warranty set forth below is given by KANOMAX JAPAN, Inc. (hereafter 

referred to as “KJI”) with respect to the KANOMAX  brand  airflow meter, and its 

attachment parts including other accessories (hereafter referred to as “PRODUCT”) 

purchased directly from KJI or from and authorized distributor. 

 

Your PRODUCT, when delivered to you in new condition in its original container, is 

warranted against defects in materials or workmanship as follows: for a period of 

one  (1) years from the date of original purchase, defective parts or a defective 

PRODUCT returned to KJI, as applicable, and proven to be defective upon inspection, 

will be exchanged for a new or comparable rebuilt parts, or a refurbished PRODUCT 

as determined by KJI. Warranty for such replacements shall not extend the original 

warranty period of the defective PRODUCT. 

   

This limited warranty covers all defects encountered in normal use of the PRODUCT, 

and does not apply in the following cases: 

(1)

 

Use of parts or supplies other than the PRODUCT sold by KJI, which cause 

damage to the PRODUCT or cause abnormally frequent service calls or 

service problems. 

(2)

 

If any PRODUCT has its serial number or date altered or removed. 

(3)

 

Loss of damage to the PRODUCT due to abuse, mishandling, alteration, 

improper packaging by the owner, accident, natural disaster, electrical 

current fluctuations, failure to follow operation, maintenance or 

environmental instructions prescribed in the PRODUCT’s operation manual 

provided by KJI, or service performed by other than KJI. 

 

NO IMPLIED WARRANTY, INCLUDING ANY IMPLIED WARRANTY OF 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, APPLIES TO THE 

PRODUCT AFTER THE APPLICABLE PERIOD OF THE EXPRESS LIMITED WARRANTY 

STATED ABOVE, AND NO OTHER EXPRESS WARRANTY OR GUARANTY, EXCEPT AS 

MENTIONED ABOVE, GIVEN BY ANY PERSON OR ENTITY WITH RESPECT TO THE 

PRODUCT SHALL BIND KJI. KJI SHALL NOT BE LIABLE FOR LOSS OF STORAGE 

CHARGES, LOSS OR CORRUPTION OF DATA OR ANY OTHER SPECIAL, INCIDENTAL 

OR CONSEQUENTIAL DAMAGES CAUSED BY THE USE OR MISUSE OF, OR INABILITY 

TO USE OR CONSEQUENTIAL DAMAGES CAUSED BY THE USE OR MISUSE OF, OR 

INABILITY TO USE, THE PRODUCT, REGARDLESS OF THE LEGAL THEORY ON WHICH 

THE CLAIMS IS BASED, AND EVEN IF KJI HAS BEEN ADVISED OF THE POSSIBILITY 

OF SUCH DAMAGES. IN NO EVENT SHALL RECOVERY OF ANY KIND AGAINST KJI 

BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE PRODUCT SOLD BY 

KJI AND CAUSING THE ALLEGED DAMAGE.  WITHOUT LIMITING THE FOREGOING, 

THE OWNER ASSUMES ALL RISK AND LIABILITY FOR LOSS, DAMAGE OF, OR 

INJURY TO THE OWNER AND THE OWNER'S PROPERTY AND TO OTHERS AND THEIR 

PROPERTY ARISING OUT OF USE OR MISUSE OF, OR INABILITY TO USE, THE 

PRODUCT NOT CAUSED DIRECTLY BY THE NEGLIGENCE OF KJI.  THIS LIMITED 

WARRANTY SHALL NOT EXTEND TO ANYONE OTHER THAN THE ORIGINAL 

PURCHASER OF THE PRODUCT, OR THE PERSON FOR WHOM IT WAS PURCHASED 

AS A GIFT, AND STATES THE PURCHASER'S EXCLUSIVE REMEDY.

 

 

After Service 

When you have a problem with your instrument, please check out  

“Troubleshooting” first.   

 

If that does not solve the problem, please contact your local distributor or call our 

service center. (See last page for contact information.)   

 

During the warranty period, we will repair at no charge a product that proves to 

be defective due to material or workmanship under normal use. (Kanomax Limited 

Warranty.) 

   

Repair after warranty expiration:   

Upon request, we will repair the instrument at the customer’s expense, if the 

instrument’s performance is found to be recoverable by providing the repair. 

 

             

Replacement parts are available for minimum period of five (5) years after   

termination of production. This storage period of replacement parts is considered 

as 

the period during which we can provide repair service.    For further information, 

please contact your local distributor or our service center. 

 

 

Summary of Contents for TABmaster Mini

Page 1: ...TABmaster Mini Model 6750 User s Manual...

Page 2: ...flow is detected by the 16 individual pressure sensors and then the average result is displayed You can also set the atmospheric pressure manually to minimize differences due to changes in atmospheric...

Page 3: ...l indicates a prohibition Do not take the prohibited action shown inside of or near this symbol e g the disassembly prohibition symbol is shown on the left This symbol indicates a mandatory action A s...

Page 4: ...he instrument may not function properly out of the specified operating conditions Remove the batteries from the battery compartment when storing the instrument for a long period Do not leave exhausted...

Page 5: ...creen with a sharp pointed object or with excessive pressure It may cause distortion of the screen or a malfunction A rapid temperature change may cause a malfunction of the screen When storing the in...

Page 6: ...ing the Power ON OFF 12 Operating the Instrument 13 Chapter 4 Taking a Measurement 14 Main Screen 14 Taking a Measurement and Storing the Data 14 Chapter 5 Menu Operation 16 Displaying the Menu Screen...

Page 7: ...Body External structure Internal structure Sampling Tube Matrix Measures airflow at 16 measuring points Main body Indicator Hood Support pole Rectifying honeycomb Pole mounting hole Airflow detecting...

Page 8: ...sion Rod Liquid crystal display Operation button Battery Cover Cover Lock Main body connector POWER Button Frame Support Pole Clear hood Hood edge urethane rubber Extension rod Indicator Fixing jig Gr...

Page 9: ...the pole mounting hole see Fig Insert the other end of the support pole into the corner of the frame See Fig Refer to Fig for the position of the other 3 poles and repeat the above steps The support...

Page 10: ...h the jig to the extension rod Then tighten the knob to fix the jig in place Affix the indicator to the jig as shown below Loosen the nut to adjust the angle of the indicator Set the desired angle and...

Page 11: ...A batteries as shown in the battery compartment New alkaline batteries or rechargeable nickel hydrogen batteries can be used Do not use different types of batteries at the same time It will cause a ba...

Page 12: ...urning the Power On Hold down the POWER button at the top of the indicator The atmospheric pressure setting screen will automatically be displayed Start Screen Atmospheric Pressure Setting Screen Main...

Page 13: ...finition of the Operation Button on the Indicator Starts a measurement on the measurement main screen Stops the measurement on the measurement main screen Cancels the current measurement Moves back to...

Page 14: ...screen for measurement a Airflow Graph Area b Airflow and Temperature Display Area displays the measured data of airflow and temperature c Power Supply Mode displays the current power supply mode AC...

Page 15: ...ond Note The displayed airflow value is an instantaneous value of every second To interrupt the ongoing measurement press the button The final measurement value will be displayed To store the value of...

Page 16: ...can be set 1 ID Set ID Setting 2 Display Read data 3 Delete Delete data 4 UPlink Send data 5 Print Print data 6 Set Bluetooth ID Set ID Setting Up to 60 IDs can be set In a single ID up to 100 measur...

Page 17: ...nal new ID cannot be created Display Read data Press or on the menu screen and select display Read Press to move on the data reading screen Tap to go back to the menu screen of the airflow value means...

Page 18: ...ete by No are available Tap to go back to the Delete screen Tap to go back to the menu screen Delete Delete All This function deletes all IDs and measurement data under the all IDs Press or to select...

Page 19: ...number to be deleted Press or to select the Data number to be deleted Hold down for 2 seconds to display the confirmation message Press to delete the selected data Press to cancel to delete UPlink Se...

Page 20: ...the connection between the main body and the PC If an error occurs in a process of connection the Error Connect Error as shown lower left will be displayed Print Setting In prior to printing confirm...

Page 21: ...by ID Print by ID Entry Press to go back to the setting screen Set the Start ID number by pressing or Hold down for 2 seconds to display the Print message Press to cancel Print by Data Entry Select 2...

Page 22: ...ng screen Hold down for 2 seconds to display the Model name serial number Hold down for 2 seconds to cancel To connect from OS device iPhone iPad to 6750 can operate 6750 from OS device and it can sen...

Page 23: ...plied a Airflow unit setting m3 h CFM Default unit m3 h b Temperature unit setting F Default unit c Atmospheric pressure unit setting kPa inHg Default unit kPa d factor setting 0 500 to 1 500 Default...

Page 24: ...ist of kPa and inHg The currently selected unit is highlighted in white as shown in the lower right figure Press or to select the unit and press to store the setting of the unit Pressing will cancel t...

Page 25: ...of settable K factor is from 0 500 to 1 500 at 0 001 intervals Note If is pressed when displaying 1 500 the setting will be changed to 0 500 if is pressed wen displaying 0 500 the setting will be chan...

Page 26: ...tion Bluetooth Digital Output USB Power Supply AA Battery x 4 AC adaptor Option Dimension of the hood 355 355 mm Weight 1 5 kg Accessories Indicator Indicator Fixing Jig Extension Rod Carrying Case Ho...

Page 27: ...cannot be created The ID has already been a new one Use the current ID to measure and store the data ID numbers are fully assigned If the number of the IDs has reached 60 delete some IDs Printed data...

Page 28: ...NTIONED ABOVE GIVEN BY ANY PERSON OR ENTITY WITH RESPECT TO THE PRODUCT SHALL BIND KJI KJI SHALL NOT BE LIABLE FOR LOSS OF STORAGE CHARGES LOSS OR CORRUPTION OF DATA OR ANY OTHER SPECIAL INCIDENTAL OR...

Page 29: ...anomax usa com JAPAN KANOMAX JAPAN INC 2 1 Shimizu Suita City Osaka 565 0805 Japan TEL 81 6 6877 0183 FAX 81 6 6879 5570 URL http www kanomax co jp E Mail sales kanomax co jp CHINA Shenyang Kano Scien...

Page 30: ...30...

Reviews: