10-7 Replacement of upper knife
a.
Remove the upper knife by loosen the screw B and pushing the pressure adjustment
dial C.
b.
Set the dimple of new upper knife in the pin on upper knife bracket E.
c.
Check the position of upper knife is located in 0.5mm higher than stationary knife.
d.
Check the sharpness of knife by turning on the hand pulley.
10-8 Replacement of stationary knife
a.
Remove the knife cover base A.
b.
Remove the stationary knife B by loosen the screw C
then pushing the pressure adjustment dial D.
c.
Set the new stationary knife carefully in the
stationary knife bracket E. The position of the point
of stationary knife should be align with surface of the
support needle plate. Then tighten the screw C.
In this time, the impel of the stopper for the
stationary knife G should be match with the pin.
■
When the stationary knife was not cutting well, the knife
have to be sharpen on a whetstone. Refer to diagram.