10-9 The way of remove of cutting device
Must be remove the cutting device when the gauge
conversion or the gauge adjustment are altered.
Additionally, in case of the cutting size were fixed
less than 20mm width, widen the upper knife
bracket and the stationary knife base bracket more
than 20mm width.
<Remove>
a.
Remove side base cover B and cutting device
cover A.
b.
Open the front cover C and the side cover D.
c.
Loosen the screw E then remove the link pin F.
d.
Turn the hand pulley to positioned the needle
bar at the bottom of its stroke then loosen the
screw G to make lower position for the support
feed dog H.
e.
Remove the cutting device bracket in front.
■
A positioning pin is fit the cutting device bracket so
that move it off with screwdriver slowly.
<Replacement>
a.
Replace the cutting device I.
b.
Turn the hand pulley to positioned the needle
bar at the top of its stroke then adjust the tip of
support feed dog to positioned 1.2mm higher
from the surface of support needle plate in
condition of the support presser foot is the down
position.
c.
Fit the connecting link M into the upper knife
connecting lever N then put the link pin F into
the hole.
d.
Replace the cutting device bracket cover A and
side cover base B.
■
Re-adjust the cutting width. Refer to 10-3.