14) Measure the distances:
                                        Δa= |

a2

-

a1

|

                                        Δb= |

b1

-

b2

|

15) The difference | Δa – Δb| should be no more than 3 mm,
      otherwise send the laser level to a qualified technician for          
      repair.

A

B

Figure # 4

C

a2

0.5m

X

2m

b1

X

b2

X

a1

X

180°

Summary of Contents for Prolaser 3D All-Lines

Page 1: ...Prolaser 3D All Lines Model No 883 User Manual Li ion 165 50m RECHARGEABLE Up to 60m 200 4 AA INCLUDED...

Page 2: ...designed for a very broad range of professional and DIY jobs including Hanging cabinets and shelves Setting floor and wall tiles Drywall installation and hanging acoustic ceilings Framing and aligning...

Page 3: ...3 CONTENTS Features 4 Safety instructions 5 6 Battery installation Safety 7 8 Overview 9 Operating instructions 10 12 Maintenance 13 Field calibration test 14 23 Specifications 24 Warranty 25...

Page 4: ...y a detector Max indoor working range 20 m 65 with red goggles The max detectable range of the laser in pulse mode is 60m 200 Manual mode allows angular layout marking IP65 Rated for water and dust pr...

Page 5: ...level Do not look into a laser beam using magnifying optical devices such as binoculars or a telescope since it will increase the level of eye injury WARNING This product contains lead in soldered joi...

Page 6: ...0 C or above 50 C 14 F to 122 F Do not operate the laser in explosive atmospheres such as flammable liquids gases or dust Sparks can cause ignition When not in use remove the battery engage the pendul...

Page 7: ...uded Installation 1 Press down the latch of the battery cover 2 Insert the Li Ion battery pack or the battery compartment with the 4 AA Alkaline batteries with the terminal contacts forward according...

Page 8: ...arging the LED indicator on the charging adaptor will be red and turn green when the battery is fully charged 1 Charger 2 Charging adaptor 3 LED indicator 4 Rechargeable battery WARNING Battery can de...

Page 9: ...ypad a Beam Selector Manual mode button b Beam Battery indicator c Pulse Mode button d Pulse Mode indicator 3 Horizontal laser beam window 4 Forward vertical laser beam window 5 Side vertical laser be...

Page 10: ...rtical side beam instead of the horizontal beam 4 Additional click on the beam selector button will turn on a 360 vertical front beam in addition to the side vertical beam 5 One more click on beam sel...

Page 11: ...ed angle 4 To choose another beam briefly press the beam selector button a it will turn on a 360 vertical side beam instead of the horizontal beam 5 An additional click on the beam selector button a w...

Page 12: ...the laser beams 1 The pulse mode can be activated both in Automatic and Manual mode 2 Turn on the laser level to the required mode 3 Press the Pulse mode button c to activate it The Pulse mode indicat...

Page 13: ...e laser level with a clean soft cloth Do not use solvents Although the laser level is dust and dirt resistant to a certain degree don t store in dusty places as long term exposure may damage internal...

Page 14: ...ck the perpendicularity between the 2 vertical beams 1 Checking the Height Accuracy of the cross created by the lateral 5 Horizontal lines Up and down deviation 1 Set up the laser on a table or on the...

Page 15: ...Reposition the laser and verify that the 2 vertical lines pass through a1 and c1 7 Mark on wall B the center of the cross beams as b1 see figure 2 A B Figure 1 C a1 0 5m c1 X 2m X approximately 5m A B...

Page 16: ...Beam Selector a twice to project all 3 lasers beams 10 Verify that the vertical line passes through a1and b1 11 On wall B mark the center of the cross beams as b2 see figure 3 12 Turn the laser 180 Re...

Page 17: ...4 Measure the distances a a2 a1 b b1 b2 15 The difference a b should be no more than 3 mm otherwise send the laser level to a qualified technician for repair A B Figure 4 C a2 0 5m X 2m b1 X b2 X a1 X...

Page 18: ...om wall A and 2 meters from wall C 3 Unlock the pendulum and press the Beam Selector a twice to project all 3 lasers beams 4 Direct the cross lines of the horizontal beam and the forward vertical beam...

Page 19: ...k the pendulum and press the button to project the vertical forward beam 4 towards the plumb line 5 Turn the laser so the vertical beam will merge with the plumb line below the hanging point 6 Mark po...

Page 20: ...more than 1mm otherwise send the laser level to a qualified technician for repair 4 Checking the Accuracy of the side Vertical beam 5 For the second vertical beam repeat the previous marking procedur...

Page 21: ...he button Beam Selector a twice to project the forward and the side vertical beams 3 Mark the center of the side vertical beam in 3 places Point a1 on the left wall A in the middle of the vertical lin...

Page 22: ...through c1 on the table and the forward laser beam passes through the marks a1 and b1 on the walls A and B respectively 6 Mark as c3 the center of the side vertical beam on wall C at the same height a...

Page 23: ...23 7 The distance between c2 and c3 should be no more than 1 5mm otherwise send the laser level to a qualified technician for repair c3 X c1 X X a1 2 5m 2 5m A b1 X B C Figure 8 5m X c2...

Page 24: ...2 5 Laser line width 2 mm 0 5mm 5m 0 10 0 02 at 20 Wavelength 633 643nm Laser Class II Power supply 2600mAh Li Ion battery 7 4V or 4 AA Alkaline batteries Battery life Up to 12 hours of continuous ope...