CAN RANGER OPERATION
23
OPTION SETUP
Using the buttons on the CAN
Ranger Receiver, navigate
through the LCD screens to
CALIBRATION. Press <SET>.
Use the arrow buttons to
enter the password 1262.
Then press the right/FWD
arrow to get to the OPTION
SETUP screen:
OPTION SETUP
←
PUSH SET
→
Push <SET>.
After a help screen (press
→
to
move
on),
the
TILT
enable/disable
screen
will
appear:
TILT DIS
THEN PUSH SET
Use
↑
or
↓
to toggle between
ENABLE or DISABLE for the
Tilt function. If your crane
basket has the Tilt feature
and tilt valve, you want to set
this
to
ENABLE
(ENB).
Otherwise disable it (DIS). If
you leave it enabled but do
not have the feature, you will
get errors indicating that
there are output errors.
When you have enabled or
disabled the Tilt feature, press
<SET>.
The next option is TILT AUTO.
The screen will appear:
TILT AUTO DIS
THEN PUSH SET
Use
↑
or
↓
to toggle between
ENABLE or DISABLE for the
Automatic Tilt feature. If your
crane has the Tilt outputs, a
the tilt sensor required for this
feature, you want to set this
to ENABLE (ENB). Otherwise
disable it (DIS).
When you have enabled or
disabled
the
TILT
AUTO
feature, press <SET>.
If you enabled the Automatic