System Ref. Vertex PN 7000
Shock Absorber
Ref. PN 7000 (02)
Wire Rope (with one end having a
swaged loops)
Ref. PN 9XXXSL (where XXX is the
length of the wire rope meters
Wire Rope Cap
Ref. PN 7000 (12)
Tensioner
Ref. PN 7000 (05)
Extremity Plates for Two Ladder Rungs
Ref. PN 7000 (13)
Rope Grab
Ref. RG-02 112
Intermediate
Ref. PN 2001(04)
Set of U-bolts and Thimbles
Ref. PN 6000 (01)
Step 01 - Installation of The Mounting Bracket (Top & Bottom)
The System PN 7000 is installed in the following way:
Step 1A: Installation of the Mounting Bracket Ref. PN 7000 (01) on
the Upper Ladder Rung:
The mounting brackets can be installed on different sections of the ladder
rung with or without the help of the two channel grips and fastened on the
same with the help of the given fasteners. The drawings below illustrate
the position of the channel grips for different sections.
COMPATIBLE
SUPPORT SECTION
PROCESS
Recommended Torque:
VERTICAL LIFE LINE SYSTEM
Ref. PN 7000
MOUNTING BRACKET
Ref. PN 7000
03
02
Step 1A :
on the Upper Ladder Rung
Installation of the Mounting Bracket Ref. SA12 .
Step 1A
Step 1B
Step 1C
Some Structures have brackets welded for fall protection. In Such cases.
an eye bolt SA 12 may be used as the mounting bracket, SA12 is certified
to EN 795.
Step 1B :
on the Upper Ladder Rung
Installation of the Mounting Bracket Ref. PN 7000 (13)
Step 1C: Installation of the Mounting Bracket Ref. PN 7000 (21)
on the Upper Ladder Rung
The PN 7000(13) brackets is fixed on two rungs of the ladder
The mounting bracket PN 7000(21) is used to hold the life line on a
monopole up till 120 mm diameter.