English
9.808-230.0 Rev. 01 (03/20)
63
Note
Bp variant:
Faults
Faults with display
Display
Correction
ERR B
Check if foreign objects block the brush; remove foreign object if required.
ERR T
Check the circuit of the suction turbine.
LOW BAT
Charge battery.
ERR TEMP
Allow device to cool down.
HandsOff
Release the safety switch and wait until the operating hours or the battery status
are displayed. Then operate the safety switch again.
ERR REL
Set the programme selector switch to "OFF", release the safety switch, wait for 3
seconds, restart.
ERR PWM
Check voltage level.
Faults without display on the console
Failure
Correction
Appliance cannot be started
Turn the program selection switch to the desired programme.
Operate the safety switch.
Check battery; charge it if required.
Make sure that all battery terminals are connected.
Insufficient water quantity
Check fresh water level, refill tank if necessary.
Increase the water volume on the regulating knob for water volume.
Insufficient vacuum performance
Clean the seals between waste water tank and cover and check for tightness, re-
place if required.
Wastewater reservoir is full; shut off the appliance and empty the wastewater
reservoir
Clean the fluff filter.
Clean the vacuum lips on the vacuum bar, replace if required
Check if the cover on the dirt water discharge hose is closed
Check the setting of the vacuum bar.
Check suction hose for blockages; clean if required.
Check the suction hose for tightness; replace if required.
Insufficient cleaning result
Check the brushes for wear, replace if required.
Brush does not turn
Check if foreign objects block the brush; remove foreign object if required.
If over-current switch in the electronics system has been triggered, turn pro-
gramme selection switch to "OFF". Afterwards, set it back to the desired pro-
gramme.
Vibrations during cleaning
You might need to use a softer brush.
Summary of Contents for BD 43/25 C Bp
Page 72: ...72 English 9 808 230 0 Rev 01 03 20 Note Ep variant Cable harness ...
Page 75: ...English 9 808 230 0 Rev 01 03 20 75 Indicator light voltage supply 9 763 122 0 ...
Page 150: ...Español 9 808 230 0 Rev 01 03 20 150 Nota Variante Ep arnés de cables ...
Page 226: ...Français 9 808 230 0 Rev 01 03 20 226 Remarque Variante Ep Faisceau de câbles ...