English
23
Faults
Fault
Remedy
By whom
Appliance cannot be started
Insert the battery plug on the device.
Operator
Release emergency-stop button by turning.
Operator
Check battery cable for correct sitting.
Operator
Reset control fuse (only BR).
Operator
Check battery cable for corrosion; clean, if required.
Operator
Battery capacity exhausted; recharge battery.
Operator
Check main fuse, replace if required
Operator
Device does not drive or
drives only slowly
Press the unlocking key.
Operator
Release accelerator pedal, turn the key switch to "0", turn the key switch to "1", press
the safety pedal, press unlocking key, press accelerator pedal.
Operator
Reset fuse of traction drive
Operator
Control overheated; switch off the device and let it cool down for 15 minutes.
Operator
Front wheel does not grip in due to high brush contact pressure; reduce brush contact
pressure.
Operator
Device does not brake
Deactivate immobilising brake; press the unlocking lever upward to activate it.
Operator
No or inadequate suction
power
Reset suction turbine fuse (only BR).
Operator
Empty the dirt water reservoir.
Operator
Check the setting of the vacuum bar.
Operator
Clean the seals between dirt water reservoir and cover and check for tightness, replace
if required.
Operator
Clean the vacuum lips on the vacuum bar, turn or replace if required
Operator
Check suction hose for blockages; clean if required.
Operator
Check connection between suction hose and vacuum bar and suction hose and lid of
the dirt water tank.
Operator
Check the suction hose for tightness; replace if required.
Operator
Check if the cover on the dirt water discharge hose is closed
Operator
Check the setting of the vacuum bar.
Operator
Clean the floater in the dirt water tank.
Operator
Insufficient cleaning result
Set/ adjust contact pressure.
Operator
Check the brushes for wear, replace if required.
Operator
Check brushes for wear and tear, clean.
Operator
Check whether the detergent and brushes are suitable for the cleaning task.
Operator
Brushes do not turn
Reset fuse of brush drive.
Operator
Check the brushes for blockage due to foreign particles, remove them if found.
Operator
No or very little detergent so-
lution gets added
Check level of detergent solution in the fresh water tank; refill, if required.
Operator
Reset pump fuse (only BR).
Operator
Increase detergent dosing.
Operator
Check fresh water sieve and filter; clean if required.
Operator
Accessories
Description
Part no.:
Description
Piece
Machine
requires
piece
Battery changing kit
8.601-121.0 consists of: battery trough, cable set, locking set, 2
transport cars
1
1
Battery
6.654-141.0 12V/105 A, maintenance-free (Gel),
1
3
Charger
6.654-229.0 36V, for maintenance-free batteries
1
1
BR
Description
Part no.:
Description
Piece
Machine
requires
piece
Brush roller, white (soft)
8.628-390.0 For polishing and cleaning sensitive floors.
1
1
Brush roller, red (medium, standard) 8.628-389.0 Also for regular cleaning of heavily dirtied floors.
1
1
Brush roller, green (hard)
8.628-391.0 For thoroughly cleaning heavily dirtied floors and for
removing the coating (for e.g. of wax, acrylate).
1
1
w w w . m o t r a l e c . c o m / s e r v i c e - c o m m e r c i a l @ m o t r a l e c . c o m / 0 1 . 3 9 . 9 7 . 6 5 . 1 0
Summary of Contents for BD 60/95 RS Bp
Page 2: ...www motralec com service commercial motralec com 01 39 97 65 10 ...
Page 319: ...www motralec com service commercial motralec com 01 39 97 65 10 ...
Page 320: ...www motralec com service commercial motralec com 01 39 97 65 10 ...
Page 321: ...www motralec com service commercial motralec com 01 39 97 65 10 ...
Page 322: ...www motralec com service commercial motralec com 01 39 97 65 10 ...