English
17
Please observe the following warning notes
when handling batteries:
Danger
Danger of explosion. Do not put tools or
similar on the battery, i.e. on the terminal
poles and cell connectors.
Risk of injury. Ensure that wounds never
come into contact with lead. Always clean
your hands after having worked with batter-
ies.
The Bp package model contains a built-in
battery.
Î
Unscrew the locking screw of the bat-
tery cover.
Î
Tilt the battery cover backwards.
Î
Push the lock of the battery insert to-
wards the left and tilt it downward.
Î
Pull the battery insert towards the rear.
Î
Place the batteries in the trough of the
battery insert.
Î
Connect poles with the enclosed con-
necting cables.
몇
Warning
Pay attention to correct poles.
Î
Connect the connection cable to the
free battery poles (+) and (-).
Î
Push the battery insert towards the
front.
Î
Lock in the battery insert lock.
몇
Warning
Charge the battery before commissioning
the machine.
Note
The device is equipped with a safety mech-
anism to prevent total discharge, i.e. when
the permissible minimum capacity is
reached, then the machine can only be driv-
en and rest water can be sucked off. The
symbol for 'full discharge protection on'
starts blinking on the display.
Î
Drive the machine directly to the charg-
ing station; avoid any steep gradients in
the process.
Note
While using other batteries (for e.g. batter-
ies from other manufacturers) the total dis-
charge protection level must be reset by the
Kärcher aftersales service according to the
respective battery.
Danger
Risk of electric shock. Observe supply net-
work and fuse protection - see "Charger".
Only use the charger in dry rooms with suf-
ficient ventilation!
Note
Average charging time is approx. 10 hours.
The recommended chargers (matching the
batteries used) are regulated electronically
and will automatically switch off the charg-
ing process.
Danger
Danger of explosion. Wet batteries can only
be charged with opened battery cover.
Î
Unscrew the locking screw of the bat-
tery cover.
Î
Tilt the battery cover backwards.
Î
Remove battery plug and join it to the
charging cable.
Î
Connect the charger to the mains and
turn it on.
Î
Switch off the charger and remove the
plug from the socket.
Î
Pull the battery cable from the charger
cable and connect it to the machine.
Î
Tilt the battery cover towards the front
and tighten the locking screw.
Î
Add distilled water one hour before the
charging process comes to an end; fol-
low the correct acid level. There are
corresponding indicators on the battery.
At the end of the charging process, all
cells must gas.
Danger
Danger of causticization!
–
Adding water to the battery in its dis-
charged state can cause the acid to
leak.
–
Use safety glasses while handling bat-
tery acid and follow the safety instruc-
tions to avoid personal injury or damage
to clothes.
–
Should the acid spray on to the skin or
clothes, rinse immediately with lots of
water.
몇
Warning
Risk of damage!
–
Use only distilled or desalinated water
(VDE 0510) for filling the battery.
–
Do not add any substances (so-called
performance improving agents), else
warranty claims will not be entertained.
Batteries and chargers are available in spe-
cialised stores.
If you use wet batteries in the BAT model,
then follow the following instructions:
– It is necessary to conform to the maxi-
mum battery dimensions.
– The battery cover needs to be opened
while charging wet (maintenance-free)
batteries.
– While charging wet batteries, follow the
specifications of the battery manufacturer.
Before Commissioning
Batteries
Observe the directions on the bat-
tery, in the instructions for use
and in the vehicle operating in-
structions
Wear eye protection
Keep children away from acid and
batteries
Danger of explosion
Fire, sparks, naked flames and
smoking must be strictly avoided
Danger of chemical burns
First aid
Warning note
Disposal
Do not throw the battery into the
regular waste
Insert batteries and connect
Charging battery
After charging
Further, in case of maintenance-free
batteries (wet batteries):
Recommended batteries
Battery set
Order No.
3 x 12V/105 A, mainte-
nance-free (Gel)
6.654-141.0
Recommended chargers
Charger
Order No.
36V, for maintenance-
free batteries
6.654-229.0
Maximum battery dimensions
Length
Width
Height
406 mm
533 mm
432 mm
www.motralec.com / service-commercial@motralec.com / 01.39.97.65.10
Summary of Contents for BR 60/95 RS Bp Pack
Page 2: ...www motralec com service commercial motralec com 01 39 97 65 10...
Page 301: ...301 5 0 0 10 1 0 BR 50 100 www motralec com service commercial motralec com 01 39 97 65 10...
Page 313: ...313 0 0 10 1 0 BR 50 100 200 www motralec com service commercial motralec com 01 39 97 65 10...
Page 319: ...www motralec com service commercial motralec com 01 39 97 65 10...
Page 320: ...www motralec com service commercial motralec com 01 39 97 65 10...
Page 321: ...www motralec com service commercial motralec com 01 39 97 65 10...
Page 322: ...www motralec com service commercial motralec com 01 39 97 65 10...