This Manual remains the property of the Manufacturer; it may not be reproduced or copied, even partially.
Instruction Manual
High pressure piston pumps
TXT Series
Doc. code M.I. TXT-21
Rev. 1
Page 17 of 35
For pharmaceuticals
In potentially explosive atmospheres (see the specific Hawk product range)
The Manufacturer reserves the right to review the terms of the guarantee if the equipment is used for any
other purpose than those mentioned above.
5
INSTALLATION AND ASSEMBLY
Read this chapter with due care before starting to install the machine.
Failure to install the pumping system correctly can result in injury or damage to property: it is important
to follow all the points below.
General scheme:
A)
Tank or mains water supply
B)
Shut-off valve
C)
Suction filter
D)
Auxiliary pump
E)
Suction pressure gauge
F)
Delivery pressure gauge
G)
Safety valve
H)
Pressure damper
I)
By-pass and control valve
J)
Nozzle
a)
Supply pipe line
b)
Delivery pipe line
c)
Safety valve release pipe line
d)
By-pass pipe line
e)
Valve outlet pipe line