Select the pressure in the
first line and go down the
table to the flow rate factor
that is closest to that of the
pump, rounded down, to
get the best type of nozzle
to
achieve
the
values
followed. To be sure the
pressure ratings will remain
constant over time, choose
a nozzle matching the flow
rate factor immediately
below the next one (in the
example, the value is circled
in green).
This Manual remains the property of the Manufacturer; it may not be reproduced or copied, even partially.
Instructions Manual
High pressure piston pumps
GXT – GXT HT – GPX SERIES
Doc. code M.I. GXT-18
Rev. 1
Page 22 of 35
NOZZLE TABLE:
the table below is an example of how to choose the nozzle correctly based on the pump’s specifications (maximum pressure and flow rate factor). The table gives an
example (pump with Pmax=100 bar and Flow Rate =15 l/min).