International Service Information

International Service Information

June 24th, 1999

HD 1050 B

New Unit Information

1. Servopress handgun is open.

When the handgun is completely open, water

flows from the pressure chamber (7) through the

non-return valve (6) and both injectors (2+4) to

the high-pressure outlet (1).

The ball (9) is pressed against the valve seat by

the pump pressure, thus sealing the connection

bore (12) to the suction chamber (11).

The pressure gauge (5) indicates the operating

pressure.

The pressure in the connection bore (17) is

approx. 30 bar less due to the injector influence

(4) (control pressure).

2. Servopress handgun is partly closed.

When the handgun is partly closed, the pressure

in the pressure chamber (7) does not increase.

Due to the decreased water flow rate, the

influence of the injector (4) is reduced so that the

control pressure in the connection bore (17)

increases. The increasing control pressure

pushes the overflow valve spindle (16) against

the spring (14) and slightly to the right. The tip of

the spindle pushes the ball (9) off its seat so that

part of the water can flow through the connection

bores (8) and (12) to the suction chamber (11).

3. Servopress handgun is completely

     closed.

When the handgun is completely closed, the

pressure in the pressure chamber (7) increases.

The increased control pressure pushes the

overflow valve spindle (16) via the connection

bore (17) against the spring (14) completely  to

the right. The tip of the spindle pushes the ball

(9) off its seat, so that the entire water volume

can flow through the connection bores (8) and

(12) to the suction chamber (11).

As soon as the handgun is closed, the non-return

valve (6) closes. Therefore the complete

pressure  in the system between handgun and

non-return valve (6) is trapped.

The pump continues running in circulation mode.

4. Servopress handgun is opened.

When the handgun is opened, the entire pressure

in the system dercreases.

The overflow valve spindle (16) is pushed back

to its original position to the left via the spring

(14). The spring (10) and the pump pressure of

the connection bore (8)  push the ball  (9) back

onto the valve seat.

The connection bore (8) is thereby closed and

the operating pressure can be built up again.

Function of overflow valve

Summary of Contents for HD 1050 B Cage

Page 1: ...Page 1 10 InternationalServiceInformation International Service Information June 24th 1999 HD 1050 B New Unit Information HD 1050 B 1 810 987 5 905 950...

Page 2: ...connection 2 Pressureandflowcontrol 3 Servopresshandgun 4 Spraylance 5 Three waynozzle 6 Cleaningagentmeteringvalve 7 Cleaning agent suction hose 8 High pressurepump 9 Engine 10 High pressureconnectio...

Page 3: ...B New Unit Information Technical features pump 1 Pressure gauge 2 Non returnvalve 3 Pressurevalve 4 Oilreservoir 5 Shaftseal 6 Swash plate bearing 7 Swash plate 8 Axial roller bearing 9 Oil drain plu...

Page 4: ...ngagentconnection 4 Controlpressureinjector 5 Pressure gauge 6 Screwplugfornon returnvalve 7 Pressurechamber 8 Connection bore from pressure chamber to ball 9 9 Ball 10 Spring 11 Suctionchamber 12 Con...

Page 5: ...tip of the spindle pushes the ball 9 off its seat so that part of the water can flow through the connection bores 8 and 12 to the suction chamber 11 3 Servopress handgun is completely closed When the...

Page 6: ...elever 2 Inner bowden cable clamping screw 3 Outer bowden cable clamp 4 Throttleleverstopscrew 5 Bowden cable 6 Adjustingscrewwithlockingnut 7 r p m regulator 1 Switch off engine and release pressure...

Page 7: ...nd operate the unit 3 Close shut off cock 1 slowly until flow rate has achieved 6 7 to 7 5 litres min see technical data This corresponds to the smallest servopress setting flow rate measured by litre...

Page 8: ...to 200 bar With this operating pressure the corresponding operating r p m must also be achieved see technical data 3 Close and open servopress handgun several times and check adjustment 4 Open servopr...

Page 9: ...pressure and flow rate Check high pressure nozzle replace if required Check water inlet filter clean if required Check engine speed adjust if required Check spring at overflow valve adjust if require...

Page 10: ...1 mechanicalversion The technical data sheet is on the next edition of the spare parts CD ROM DISIS and in the Intranet KMN folder Central Service Info Int l Technical Data Further operating handbooks...