– 8

Nozzle is set to "High pressure"

Set nozzle to "CHEM". 

Detergent suction hose with filter is 
leaky or blocked

Check/ clean detergent suction hose 

with filter. 

Backflow valve in the connection of the 

detergent suction hose is jammed

Clean/ replace backflow valve in the con-

nection of the detergent suction hose. 

Detergent dosing valve is closed or 

leaky/ blocked

Open or check/clean detergent dosing 
valve. 

If malfunction can not be fixed, the de-
vice must be checked by customer serv-
ice.

The warranty terms published by our com-
petent sales company are applicable in 
each country. We will repair potential fail-
ures of the appliance within the warranty 
period free of charge, provided that such 
failure is caused by faulty material or de-
fects in fabrication.

Only use accessories and spare parts 
which have been approved by the man-
ufacturer. The exclusive use of original 
accessories and original spare parts 
ensures that the appliance can be oper-
ated safely and troublefree.

At the end of the operating instructions 
you will find a selected list of spare parts 
that are often required. 

For additional information about spare 
parts, please go to the Service section 
at www.kaercher.com. 

We hereby declare that the machine de-

scribed below complies with the relevant 

basic safety and health requirements of the 

EU Directives, both in its basic design and 

construction as well as in the version put 

into circulation by us. This declaration shall 

cease to be valid if the machine is modified 

without our prior approval.

5.957-559

The undersigned act on behalf and under 

the power of attorney of the company man-

agement.

Authorised Documentation Representative
S. Reiser

Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Phone: +49 7195 14-0
Fax: +49 7195 14-2212

Winnenden, 2010/07/14

Detergent is not getting sucked in

Warranty

Accessories and Spare Parts

EC Declaration of Conformity

Product:

High-pressure cleaner

Type:

1.810-xxx

Relevant EU Directives

2006/42/EC (+2009/127/EC)

2004/108/EC

2000/14/EC

Applied harmonized standards

EN 60335–1

EN 60335–2–79

EN 61000–6–2: 2007

Applied national standards

CISPR 12

Applied conformity evaluation method

2000/14/EC: Appendix V

Sound power level dB(A)

HD 1050 B

Measured:

106

Guaranteed:

108

HD 1050 DE

Measured:

109

Guaranteed:

110

CEO

Head of Approbation

19

EN

Summary of Contents for HD 1050 B Cage

Page 1: ...sch 3 English 12 Fran ais 21 Italiano 31 Nederlands 41 Espa ol 50 Portugu s 60 Dansk 70 Norsk 79 Svenska 88 Suomi 97 106 T rk e 117 126 Magyar 137 e tina 147 Sloven ina 156 Polski 165 Rom ne te 175 Sl...

Page 2: ...2...

Page 3: ...tection EN 1 Symbols in the operating in structions EN 1 Device elements EN 2 Symbols on the machine EN 2 Proper use EN 2 Safety instructions EN 2 Safety Devices EN 3 Start up EN 3 Operation EN 4 Tran...

Page 4: ...ning tools etc Use only the high pressure jet without detergent for cleaning facades terrac es garden equipment etc For stubborn dirt we recommend the use of the dirt blaster as a special ac cessory D...

Page 5: ...de Thus the permissi ble working pressure is not exceeded The overflow valve is set by the manu facturer and sealed Setting only by customer service Danger Risk of injury Device tubes high pressure ho...

Page 6: ...ray lance attached Check and ensure proper fitting of the spray lance prior to each use The screw connection of the spray lance must be fingertight Danger Place the appliance on firm surface The high...

Page 7: ...f the environment use detergent economically Follow the safety instructions for using de tergents K rcherdetergentsensuresmoothfunctioning Please consult us or ask for our catalogue or our detergent i...

Page 8: ...ional frost protection agents through the appliance A certain corrosion protection is achieved with this as well Caution Risk of injury and damage Observe the weight of the appliance when you transpor...

Page 9: ...uctions of the engine manufacturer Operating speed of the engine is too low Check operating speed of the engine refer to technical data Nozzle is set to CHEM Set nozzle to High pressure Nozzle is bloc...

Page 10: ...rts that are often required For additional information about spare parts please go to the Service section at www kaercher com We hereby declare that the machine de scribed below complies with the rele...

Page 11: ...ssure MPa bar 4 23 40 230 4 23 40 230 Flow rate l h l min 400 780 6 7 13 400 900 6 7 15 Nozzle size 047 047 Max excess operating pressure safety valve MPa bar 25 250 25 250 Oil quantity pump l 0 35 0...

Page 12: ......

Reviews: