background image

5

English

 2. Preparing the cleaner for use

Unpack the cleaner

• When unpacking the cleaner, check the

contents of the packaging. If there has been any
damage in transit inform the dealer.

• Do not dispose of the packaging with the

household rubbish, hand it in at the appropriate
collection point for recycling.

Check the oil level

See illustrations 

1

 to 

3

 at the end of the

instructions.
• Screw out the fastening screws on the left and

right of the unit cover, remove unit cover.

• Cut off the tip on the cover to the oil reservoir.
• Check the oil level in the oil reservoir.
• Fasten the unit cover.

Mount the accessories

See illustrations 

4

 to 

6

 at the end of the

instructions.
• Mount handle (screws and nuts supplied).
• Engage the holder for handgun at the side of the

handle.

• Mount nozzle on the spray lance (see markings

on the top of the setting ring).

• Mount spray lance on the handgun.

 3. Using the cleaner for the first time

Electrical connection

Caution!  The voltage specified on the model
rating plate must correspond to the voltage
supplied.
Caution! Use an extension cable whose cable
cross-section is adequate (10 m = 2.5 mm²,
30 m = 4 mm²) and unreel it completely from
the cable drum.

• For connected loads see model rating plate/

Technical Specifications

Water connection/suction feed
operation

Connection to water main

Caution! Pay attention to the regulations of the
water supply company; according to DIN 1988,
the cleaner may not be connected direct to the
public drinking water supply. A short-term
connection via a non-return valve (Order no.
6.412-578) is allowed.

For connected loads see Technical
Specifications.

• Connect a supply hose (not supplied) to the

water outlet (15) on the cleaner and to the water
inlet (e.g. water tap).

• Open water inlet.

Suctioning water from an open container
• 
Screw suction hose with filter (Order no.

4.440-238) to the water outlet (15).

Venting the unit
• 
To vent the unit, unscrew the nozzle and leave

the unit running until the water exits with no air
bubbles.

• Switch off the unit and screw the nozzle back

on.

Summary of Contents for HD 650 *GB

Page 1: ...5 959 201 A2002757 11 01 HD 650 GB...

Page 2: ......

Page 3: ......

Page 4: ...mer Service centre taking along also the accessories and bill of sale Unit parts Please fold out illustration page at the front 1 Handgun with built in pressure gauge 2 Lever 3 Safety switch 4 Spray l...

Page 5: ...time Electrical connection Caution The voltage specified on the model rating plate must correspond to the voltage supplied Caution Use an extension cable whose cable cross section is adequate 10 m 2 5...

Page 6: ...of consideration for the environment K rcher cleaning agents guarantee trouble free operation Please seek advice or ask for our catalogue of information sheets on cleaning agents Active cleaner RM 31...

Page 7: ...ty and type see Technical Specifications Undo fastening screws 12 remove unit cover remove cover of oil reservoir Lay cleaner on its side and drain oil into a suitable container Fill slowly with fresh...

Page 8: ...ns Check all supply lines to the pump for leaks or obstructions Seek the help of Customer Service if necessary Pump is leaky Three drops per minute are allowable and can appear on the underside of the...

Page 9: ...L 7YTTP LSWI PIRKXL Q 7YTTP LSWI QMRMQYQ HMEQIXIV MRGLIW 7YGXMSR LIMKLX JVSQ ER STIR GSRXEMRIV p Q 7YTTP TVIWWYVI QE FEV 4IVJSVQERGI HEXE 3TIVEXMRK TVIWWYVI FEV PS VEXI P L IXIVKIRX MRXEOI P L 6IGSMP...

Page 10: ...lied DIN EN 60 335 1 DIN EN 61 000 3 3 1995 DIN EN 60 335 2 79 DIN EN 55 014 2 1997 DIN EN 61 000 3 2 1995 DIN EN 55 014 1 1993 National standards applied Appropriate internal measures have been taken...

Page 11: ...B 6 362 422 0 6 388 216 0 5 044 082 0 5 731 040 0 4 580 337 0 6 389 853 0 2 880 296 0 6 389 853 0 4 775 296 0 6 389 870 0 6 414 252 0 6 435 197 0 MAX MIN O I 6 304 099 0 4 763 212 0 2 880 296 0 4 760...

Page 12: ......

Reviews: