– 11
The warranty terms published by our com-
petent sales company are applicable in
each country. We will repair potential fail-
ures of the appliance within the warranty
period free of charge, provided that such
failure is caused by faulty material or de-
fects in fabrication.
–
Only use accessories and spare parts
which have been approved by the man-
ufacturer. The exclusive use of original
accessories and original spare parts
ensures that the appliance can be oper-
ated safely and trouble free.
–
At the end of the operating instructions
you will find a selected list of spare parts
that are often required.
–
For additional information about spare
parts, please go to the Service section
at www.kaercher.com.
We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements of the
EU Directives, both in its basic design and
construction as well as in the version put
into circulation by us. This declaration shall
cease to be valid if the machine is modified
without our prior approval.
5.957-554
The undersigned act on behalf and under
the power of attorney of the company man-
agement.
Authorised Documentation Representative
S. Reiser
Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Phone: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2013/02/01
Warranty
Accessories and Spare Parts
EC Declaration of Conformity
Product:
High pressure cleaner
Type:
1.210-xxx
Relevant EU Directives
2006/42/EC (+2009/127/EC)
2000/14/EC
2004/108/EC
Applied harmonized standards
EN 55012: 2007 + A1: 2009
EN 60335–1
EN 60335–2–79
Applied conformity evaluation method
2000/14/EC: Appendix V
Sound power level dB(A)
Measured:
102
Guaranteed: 104
CEO
Head of Approbation
26
EN