18
Park the machine on an even surface.
Turn the programme selector switch to
"OFF" and remove the KIK-key.
Side brush and roller brush are raised.
Activate parking brake.
Front sealing strip
Loosen the plastic screws by approx. 2
turns, do not completely unscrew them.
Set the distance between the sealing
strip and the floor so that the bottom
edge trails behind at a distance of be-
tween 10-15 mm.
Tighten the screws.
Caution:
Do not strip plastic screws!
If worn, replace.
For replacement unscrew the screws,
attach new sealing strip and retaining
plate, adjust and tighten screws.
Rear sealing strip
Loosen the plastic screws by approx. 2
turns, do not completely unscrew them.
Set the distance between the sealing
strip and the floor so that the bottom
edge trails behind at a distance of be-
tween 5 and 10 mm.
Tighten the screws.
Caution:
Do not strip plastic screws!
If worn, replace.
For replacement unscrew the screws,
attach new sealing strip and retaining
plate, adjust and tighten screws.
Side sealing strips
Loosen the plastic screws by approx. 2
turns, do not completely unscrew them.
To set the floor clearance, insert a
sheet with a thickness of between 1 and
3 mm under the sealing strip.
Adjust sealing strip.
Tighten the screws.
Caution:
Do not strip plastic screws!
If worn, replace.
For replacement unscrew the screws,
attach new sealing strip and retaining
plate, adjust and tighten screws.
몇
WARNING
Health hazard!
Wear a dust mask when working
around the dust filter. Observe safety
regulations on the handling of fine parti-
cles.
Note
: Wait at least 1 minute before remov-
ing the dust filter so that the dust can settle.
Figure: KM 125/... with 3 flat fold filters; KM
105/... has 2 flat fold filters
1 Lid with cleaning device
2 Screw
3 Support
4 Dust filter (flat-fold filter)
Unscrew the screw.
Fold the lid up and secure it by means
of the support.
Take out the dust filter.
Check dust filter.
Insert cleaned or new dust filter.
Close the lid.
Screw in the screws and tighten them.
(only with KM 125/...)
1 Protective grid oil cooler
2 Oil cooler
Check the protective grid of the oil cool-
er for contamination daily, clean if nec-
essary.
Check the inside of the oil cooler for
soiling every once in a while, remove
the protective grid and clean the oil
cooler if necessary.
Have the suction blower checked for
leaks.
Only by customer service.
Check tension of V-Belt.
Only by customer service.
The appliance (without upgrade kits) is
equipped with two fuses with 5 A fuse pro-
tection each. They are located under the
appliance cover.
If fuses are defective, contact the author-
ised aftersales service.
Additional fuses for the oil cooler
The diesel version has an additional fuse
FU20 with 30 A fuse protection. It can be
replaced by the customer in case of defect,
in order to do so, swivel the left bonnet to
the side.
Adjusting and replacing sealing strips
Check/replace dust filter
Check/clean protective grid oil cooler
Check suction blower
Checking drive belt
Replacing fuses of drive control/
electronic system
FM 31
Oil cooler engine
7.5 A
FK 31
Oil cooler contactor
5 A
45
EN
Summary of Contents for KM 105/100 R D
Page 2: ...2 ...