37
KMR 1250 B, LPG, D
Troubleshooting Information
Replace dust filter
A noticeable deposit of dust at the impeller fan
exhaust indicates a poorly installed or defective
dust filter.
–
Raise debris container (1) to half of its travel,
and secure against dropping.
–
Unsnap clip fasteners (2) on filter enclosure.
–
Swing filter enclosure (3) forward, then lift
off.
–
Unfold hand grip (4), pull out, and unlock by
means of a 90-degree turn.
–
Remove old dust filter (5).
–
Insert new dust filter (6).
–
Return hand grip (4) to original position, and
snap into place.
–
Install filter enclosure (3), and lock clip fas-
teners (2).
Check rubber sleeve
To prevent filter replacement problems caused
by premature corrosion of the locator pin (7) in
the filter receptacle, a rubber sleeve (9) was in-
stalled on units with S/N 10518 and up.
Defective or missing rubber sleeve (9) should be
replaced or retrofitted (refer to service bulletin
no. 1998-045).
Lifting filter box
Replacing dust filter
Installing rubber sleeve
Excessive Unit Dusting
1
2
2
3
4
5 / 6
1
Debris container
2
Filter enclosure clip fasteners
3
Filter enclosure
4
Hand grip
5/6 Replace dust filter
7
Locator pin
8
Compression spring
9
Rubber sleeve
2
1
3