English
5.906-472.0 Rev. 00 (08/08)
9
1
Connecting cable, suction turbine (M1)
2
De-interference capacitor (C1)
3
Appliance switch (S1)
4
Mains cable
5
Connector plug (2x), suction turbine and de-interference ca-
pacitor
6
Connector plug (2x), mains cable
7
Bracket
Î
Separate the suction turbine casing from the suction head cas-
ing (see Chapt. 5.4).
Î
Pull the appliance switch (3) out of the holder (4).
Î
Pull the connecting cable (2) of the suction turbine (6) off of the
appliance switch (3).
Î
Pull the connecting cable of the suction turbine out of the cable
slots (arrows).
Î
Remove the cover (5) from the suction turbine casing.
Î
Remove the fastening screws (8) of the suction channel cover
(7).
Î
Remove the suction channel cover (7).
5.6
Replacing the suction turbine