6
1 Menu item
2 Parameter
Select the menu item with the buttons
LEFT and RIGHT.
Press OK to open the parameter group.
Use the LEFT and RIGHT buttons to
select the parameter you want to set.
Press the OK button.
The selectable variable blinks.
Use the LEFT and RIGHT buttons to
select the variable value.
Press and hold the button for a swift
change of the variable.
Press the OK button to save the select-
ed value.
or
Press ESC to abort the change.
Press the OK button.
The selectable variable blinks.
Use the LEFT and RIGHT buttons to
select the variable value.
Press OK briefly to save the value and
to jump to the next variable.
Press the OK button for more than 1
second to save set values.
or
Press ESC to abort the change.
Press the ESC ro return to the next
higher menu.
Here you can select the gantry speed for
the individual program sections.
FW emergency mode No:
If the processed water supply is used up,
the running wash is continued with fresh
water. After the wash is completed, the sys-
tem switches to a non-operational state.
FW emergency mode Yes:
If the processed water supply is used up,
the washing operation is continued with
fresh water. The system remains ready for
operation, a message will be displayed.
Setting date, time and summer/winter time
change
Auto summer / winter time = YES:
Automatic change active. Summer time
(daylight saving time) begins on the last
sunday in March at 2:00 o'clock. Winter
time (normal time) begins on the last sun-
day in October at 3:00 o'clock.
Auto summer / winter time = NO:
No automatic time change.
The plant is open during the operating time.
The plant is locked outside the operating
time.
24 hours open:
Set beginning and end of
the operating time to the same value.
24 hours closed:
Set the end of the oper-
ating time to an earlier value than the be-
ginning of the operating time
Variable public holidays are on different
days every year. They must newly be set
every year.
On the set public holidays the operating
time selected for public holidays applies.
Note
Set the date to 00.00.00 for unused public
holidays.
Fixed public holidays are on the same day
every year.
On the set public holidays the operating
time selected for public holidays applies.
Select the parameter you want to set
Set the parameter with a variable
Setting a parameter with several varia-
bles
Exiting the menu
Speed selection
Program section
Setting range
Foam
30%...150%
Intensiv
30%...150%
HD-HD roof
30%...150%
HP side c.
30%...150%
Car
30%...120%
Transp.
30%...120%
Bus
30%...120%
Truck
30%...120%
Tanker
30%...120%
Rinsing
30%...150%
Setting selection
Date / time selection
Operating time selection
Selection of variable public holidays
Selection of fixed public holidays
8