background image

English

1 Grounded outlet
2 Grounded outlet Box
3 Grounded Pin

Save operation is in the responsibility of the 
operator.
The operator shall be familiar with the oper-
ation and function of all controls and instru-
ments before undertaking to operate the 
unit.
Before operating the unit, operators shall 
have read and be familiar with the operator’s 
manual for the particular unit being operated 
and they shall also abide by the safety rules 
and practices in the following paragraphs.
Before operating any unit, the operator shall 
be familiar with unusual operating conditions 
which may require additional safety precau-
tions or special operating instructions.

Before starting to operate the unit be in op-
erating position.
Do not start or operate the unit, any of its 
functions or attachments, from any place 
other than from the designated operators 
position.
Before leaving the operator’s position:
A bring the unit to a complete stop;

B if the unit must be on an incline, block the 

wheels.

Maintain a safe distance from the edge of 
ramps, platforms, and other similar working 
surfaces.
Do not add to, or modify the unit.
Do not block access to fire aisles, stairways 
or fire equipment.

Yield the right of way to pedestrians and 
emergency vehicles such as ambulances 
and fire trucks.
Cross railroad tracks at an angle wherever 
possible. Do not park closer than 6 ft (1800 
mm) to the nearest rail of a railroad track.
Keep a clear view of the path of travel and 
observe for other traffic, personnel, and safe 
clearances.
Under all travel conditions, operate the unit 
at a speed that will pernit it to be brought to 
a stop in a safe manner.
Do not indulge in stunt driving or horseplay.
Slow down for wet and slippery floors.
Before driving over a dockboard or bridge 
plate, be sure that it is properly secured. 
Drive carefully and slowly across the dock-
board or bridge plate, and never exceed its 
rated capacity.
When negotiating turns, reduce speed to a 
safe level consistent with the operating envi-
ronment. Make the turns smoothly.

If the unit is found to be in need of repair or 
in any way unsafe, or contributes to an un-
safe condition, the matter shall be reported 
immediately to the user’s designated author-
ity, and the unit shall not be operated until it 
has been restored to safe operating condi-
tion.
If during operation the unit becomes unsafe 
in any way, the matter shall be reported im-
mediately to the user’s designated authority, 
and the unit shall not be operated until it has 
been restored to safe operating condition.
Do not make repairs or adjustments unless 
specifically authorized to do so.

CONNECT TO A PROPERLY 

GROUNDED OUTLET ONLY

OPERATING SAFETY RULES 

AND PRACTICES

Operator Responsibility

General

Travelling

Operator care of the unit

Summary of Contents for Tornado BR 4735 ESC

Page 1: ...English E BR 4735 ESC 5 961 740 2011369 09 05...

Page 2: ...o pick up flammable or combustible liquids such as gasoline or use in areas where they may be present Connect to a properly grounded outlet only See Grounding Instruction This appliance must be ground...

Page 3: ...ucks Cross railroad tracks at an angle wherever possible Do not park closer than 6 ft 1800 mm to the nearest rail of a railroad track Keep a clear view of the path of travel and observe for other traf...

Page 4: ...fire protection equipment present in the work area Do not use open pans of fuel or flammable cleaning fluids for cleaning parts Any unit not in safe operating condition shall be removed from service...

Page 5: ...vices serve to protect the user and must not be rendered inoperational or their functions bypassed The appliance can only be started when you press the foot pedal fully downwards The machine stops whe...

Page 6: ...Please do not throw pack aging in the domestic waste but pass it on for recycling Old units contain valuable recy clable materials Batteries oil and similar substances may not be re leased into the en...

Page 7: ...irt water reservoir 9 Front wheels 10 Dirt water reservoir 11 Fresh water reservoir filler neck 12 Pedal for raising lowering the brush head 1 Operating hour counter 2 Display pump pressure 3 Power sw...

Page 8: ...in the fresh water reservoir Press the foot pedal Set the machine switch to basic clean ing Keep the machine running until the pres sure on the manometer falls Danger Risk of injury The appliance can...

Page 9: ...eaned Cleaning slighly dirty travellators escalators normally at short regular intervals At this setting the appliance works with reduced quantity of water The water pump works with regular strokes Cl...

Page 10: ...anger Risk of injury Do not push the appliance onto the escalator any further than the indi cations given below Otherwise the ma chine will get dragged off by the escalator In case of danger immediate...

Page 11: ...f Clean the inside and outside of the ma chine Rinse the tanks with clear water Store the machine in a frost free room on an even and clean floor Lock the rear wheels Remove the cordon from the travel...

Page 12: ...es intake brushes combs guide rails hoses pads stopper and front wheels Replace stopper and front wheels if required only through author ised customer service agents Check mains cable and plug for dam...

Page 13: ...n the wider rails Pull out all dirt particles from the suction nozzles do not push them in Loosen the fastening screws of the hold er for the guide rails Dismantle the guide rails Insert the guide rai...

Page 14: ...ace it Danger Risk of injury Do not drive over slopes great er than 5 Never transport the machine over the travellator escalator Lock the rear wheels Secure the machine with clamping belts and ropes s...

Page 15: ...t water reservoir for damages replace if required Check the intake brushes for wear replace if required Check suction nozzles and hose for blockages clean if required Washed steps are not clean Check...

Page 16: ...res that the ap pliance can be operated safely and trouble free At the end of the operating instructions you will find a selected list of spare parts that are often required For additional information...

Page 17: ...e travellator escalator brand set with 2 pieces Outlet combs blue Kone 6 369 519 Inlet combs black OTIS 6 369 510 Outlet combs black OTIS 6 369 520 Inlet combs green Schindler 6 369 511 Outlet combs g...

Page 18: ......

Reviews: