Operating Instructions BR/BD Trike
English
14
Information:
Start cleaning at a low contact
pressure. Gradually increase the contact
pressure until the desired cleaning result
is obtained.
A correctly set contact pressure reduces
the energy requirement and brush wear.
If the machine stops, the brush motors
stop. If the brush motors overload, the fuse
trips. In this case, the fuse must be
changed (F2, 70 A).
Caution!
The brush contact pressure must not
be set too high for polishing.
Stopping and switching off
the unit
Raise and lock the brush head
To do this, depress the brush head
pedal and lock by simultaneously tilting it
backwards.
The motor switches off automatically.
Move the unit another 1–2 m to extract
any remaining water.
Raise the suction bar.
To do this, depress the suction bar pedal
and lock by gently pushing it to the left.
The suction motor coasts for a further
10 seconds to extract remaining water out
of the suction bar and vacuum channels.
Set the key switch on the control panel
to “
O
” and remove the key.
Draining the dirty water
Caution!
Observe local regulations for
the treatment of waste water.
Take the drainage hose out of the holder
and place in a suitable receptacle. Drain
off the dirty water by opening the
metering equipment. Then rinse out the
dirty-water tank with fresh water.
Adjusting the suction bar
Rotating the suction bar
To improve the suction result on ceramic
coverings, the suction bar can be rotated by
up to 5°:
Loosen the star knobs.
Rotate the suction bar.
Tighten the star knobs.
i