23
Operations
brushes down to further loosen soil. The additional
application of solution will further assist the difficult
cleaning job.
FOR SAFETY: When using machine, go slow on
inclines and slippery services.
Emptying and Cleaning Tanks
1.
Park the machine next to a floor drain. Drain hoses
are at the front of the machine.
2.
Turn the machine power off.
Recovery Tank
1.
Open the recovery tank lid. Pull the recovery drain
hose from the mounting bracket. Open cap, then
lower hose in direction of the drain. Do not stand in
front of end of hose. Recovered solution will come
out with force.
2.
Flush the recovery tank out with clean water. Do
not use water hotter than 140°F (60°C) to clean
tank. Damage may occur.
3.
Clean debris bin.
4.
Clean off the float shut-off system and inspect for
free movement of float.
5.
Replace the drain hose cap and secure drain hose.
6.
If machine is to be stored, leave the recovery tank
lid propped open.
Solution Tank
1.
Remove the recovery tank lid.
2.
Pull the solution drain hose from its mounting
pocket. Unscrew the cap, then lower hose in direc-
tion of drain.
3.
Remove the solution tank cap.
4.
Flush the solution tank out with clean water and
run several gallons of clean water through sys-
tems. Do not use water hotter than 140°F (60°C) to
clean tank. Damage may occur.
5.
If machine is to be stored, leave solution cap off.
NOTE: Never allow solution to remain in tank.
Damage to tank, seals and valves could occur.
Optional Chemical Metering System
1.
Remove chemical container from machine and
store unused chemical. Flush chemical container
with water.
2.
Fill chemical container partway with clean water.
Press and hold prime button for 1 minute.
3.
Empty chemical container. press and hold prime
button for 30 seconds to purge chemical lines.
Chemical Metering Controls
1.
CHEMICAL METERING SYSTEM SELECTION
DIAL (OPTIONAL)
Eight position dial which controls chemical system
operation. Upper five positions turn chemical
system on and controls dilution from .5 to 4.0 oz/
gal. Three lower positions turn chemical system
off.
2.
CHEMICAL METERING SYSTEM PRIME
BUTTON (OPTIONAL)
Runs chemical pump when pressed. Press for 30
seconds to prime empty chemical system. Fill
chemical reservoir with clean water and press
prime button for one minute to flush chemical
system.
Solution Drain
Hose
Recovery Drain
Hose
Recovery Tank
Lid
86395370 Operator Manual - Chariot 3 iScrub 26
Summary of Contents for Windsor Chariot 3 iScrub 26
Page 26: ...26 Notes 86395370 Operator Manual Chariot 3 iScrub 26 ...
Page 57: ...57 Notes 86395370 Operator Manual Chariot 3 iScrub 26 ...
Page 69: ...10 Bumper 0 250 052 0 Valid on 06 03 2019 Page 5 95 ...
Page 71: ...20 Console 0 250 053 0 Valid on 06 03 2019 Page 7 95 ...
Page 73: ...30 Console Mounting 0 250 067 0 Valid on 06 03 2019 Page 9 95 ...
Page 75: ...40 Control Panel Upper 0 250 068 0 Valid on 06 03 2019 Page 11 95 ...
Page 77: ...50 Control Panel Lower 0 250 069 0 Valid on 06 03 2019 Page 13 95 ...
Page 79: ...60 Control Panel Chemical Solution Meteri 0 250 100 0 Valid on 06 03 2019 Page 15 95 ...
Page 81: ...70 Control Panel Mounting 0 250 070 0 Valid on 06 03 2019 Page 17 95 ...
Page 83: ...80 Decals 0 250 071 0 Valid on 06 03 2019 Page 19 95 ...
Page 85: ...90 Drive Mounting 0 250 072 0 Valid on 06 03 2019 Page 21 95 ...
Page 87: ...100 Frame 0 250 073 0 Valid on 06 03 2019 Page 23 95 ...
Page 89: ...110 Platform 0 250 074 0 Valid on 06 03 2019 Page 25 95 ...
Page 91: ...120 Platform Footbox Rear Wheels 0 250 075 0 Valid on 06 03 2019 Page 27 95 ...
Page 93: ...130 Rear Cover 0 250 076 0 Valid on 06 03 2019 Page 29 95 ...
Page 95: ...140 Scrub Deck Mounting Disk 0 250 082 0 Valid on 06 03 2019 Page 31 95 ...
Page 97: ...150 Scrub Brush Pads Driver Disk 0 250 084 0 Valid on 06 03 2019 Page 33 95 ...
Page 99: ...160 Solution System Disk 0 250 086 0 Valid on 06 03 2019 Page 35 95 ...
Page 101: ...170 Squeegee Disk 0 250 088 0 Valid on 06 03 2019 Page 37 95 ...
Page 104: ...180 Squeegee Swing Disk 0 250 091 0 Valid on 06 03 2019 Page 40 95 ...
Page 106: ...190 Squeegee Lift 0 250 090 0 Valid on 06 03 2019 Page 42 95 ...
Page 108: ...200 Scrub Deck Cylindrical 0 250 078 0 Valid on 06 03 2019 Page 44 95 ...
Page 111: ...210 Scrub Deck Lift Cylindrical 0 250 080 0 Valid on 06 03 2019 Page 47 95 ...
Page 113: ...220 Scrub Deck Skirts 0 250 081 0 Valid on 06 03 2019 Page 49 95 ...
Page 115: ...230 Scrub Deck Mounting Cylindrical 0 250 083 0 Valid on 06 03 2019 Page 51 95 ...
Page 117: ...240 Scrub Brush Pads Driver Cylindrical 0 250 085 0 Valid on 06 03 2019 Page 53 95 ...
Page 119: ...250 Solution System Cylindrical 0 250 087 0 Valid on 06 03 2019 Page 55 95 ...
Page 121: ...260 Squeegee Cylindrical 0 250 089 0 Valid on 06 03 2019 Page 57 95 ...
Page 124: ...7 Suction bar curved 850mm B95RS 4 777 100 0 Valid on 06 03 2019 Page 60 95 ...
Page 126: ...10 Suction bar pre assembled curved 850mm 4 035 311 0 Valid on 06 03 2019 Page 62 95 ...
Page 128: ...9000 Roller suction bar 4 035 339 0 Valid on 06 03 2019 Page 64 95 ...
Page 131: ...16 Roller suction bar 4 035 339 0 Valid on 06 03 2019 Page 67 95 ...
Page 133: ...270 Squeegee Swing Cylindrical 0 250 092 0 Valid on 06 03 2019 Page 69 95 ...
Page 135: ...280 Steering 0 250 093 0 Valid on 06 03 2019 Page 71 95 ...
Page 138: ...290 Tank 0 250 094 0 Valid on 06 03 2019 Page 74 95 ...
Page 140: ...300 Vacuum 0 250 095 0 Valid on 06 03 2019 Page 76 95 ...
Page 142: ...310 Wiring Batteries 0 250 096 0 Valid on 06 03 2019 Page 78 95 ...
Page 145: ...320 Wiring Components 0 250 097 0 Valid on 06 03 2019 Page 81 95 ...
Page 147: ...330 Battery Exchange 1 0 250 102 0 Valid on 06 03 2019 Page 83 95 ...
Page 149: ...340 Battery Exchange 2 0 250 103 0 Valid on 06 03 2019 Page 85 95 ...
Page 151: ...350 Battery Exchange 3 0 250 104 0 Valid on 06 03 2019 Page 87 95 ...
Page 153: ...360 Onboard Charger 0 250 101 0 Valid on 06 03 2019 Page 89 95 ...
Page 155: ...370 Chemical Metering Solution System Disk 0 250 098 0 Valid on 06 03 2019 Page 91 95 ...
Page 157: ...380 Chemical Metering Solution System Cyli 0 250 099 0 Valid on 06 03 2019 Page 93 95 ...