10- In case it is necessary to remove the exchange from the wall, it suffices just to lift it
upwards cautiously and pull it out.
*
KEEP IN MIND THAT IT IS ESSENTIAL TO MOUNT AND DISMOUNT THE
WALL MOUNT BARS SIMULTANEOUSLY; OR THEY MAY BE DEFORMED.
11- To mount the second rack, the top cover of the lower rack and the bottom cover of the
upper rack are removed in order to attach the cables which are to connect the racks to
each other (Caution is needed for the grounding cables, as explained in the 7
th
step.) The
BPL200 backplanes are connected to each other with the BPL200-FC and BPLSPS-FC
connection cables that come with the hardware of the auxiliary rack on delivery. There
are three such cables. Two BPL200-FC's (34-pin flat cable) are used to connect the
BPL200 backplanes to each other and the single BPLSPS-FC (5-wire cable) is used to
combine the BPL200-SPS backplanes.
1. BPL200-FC connections
2. BPLSPS-FC connection
a) BPL200-AUX
d) BPL200-SPS
b) BPL200-FC
e) BPLSPS-FC
c) BPL200-MAIN
f) BPL200-SPS