DS Series PBX Technical Reference And Installation Guide
147
NOTE: If SPS200 is not used; DCC, power inverters and SPS248 units are connected to the
external power supply.
When installing the DS200L system, after the physical connections have been made, the
instructions below should be followed in the specified order. The computer that is mentioned
as “the maintenance computer” below is a user computer in the same local area network, on
which programming work pertaining to the system is done, and which runs the Windows
operating system.
1) Power ON all the system. And turn ON PCU200 and maintenance computer.
2) Check the IP addresses of the CC cards, DCC Utility Card, PCU200 and maintenance
computer.
3) Run WinSCP program at maintenance computer. Check the “karel” directory and the
directories in it. If there is a data missing, copy it from the maintenance computer.
4) At WinSCP program, write the IP addresses of the towers and DCC block into the
“pbxcomm.conf” file. And also check the master software version from the “dsinit.conf” file.
And if redundant PCU200 block is available in the system, write the “buddy=x2” definition
into this file.
5) At SSH Secure Shell program at the karel/bin command prompt, enter “rpm –ivh –force
zr_xxx.rpm” command. By this command zipped zr_xxx.rpm software is extracted. After this,
enter the “check z_xxx” command. By this command, read-write executes (r-w-x) authorities
of all the files under karel directory are set. Furthermore, by this command, master software
version of the system is automatically written into the “dsinit.conf” file.
Summary of Contents for DS200
Page 1: ...11 2010 TECHNICAL REFERENCE AND INSTALLATION GUIDE PBX DS SERIES...
Page 2: ...DS SERIES PBX TECHNICAL REFERENCE AND INSTALLATION GUIDE NOVEMBER 2010...
Page 17: ...DS Series PBX Technical Reference And Installation Guide 7...
Page 69: ...DS Series PBX Technical Reference And Installation Guide 59...
Page 80: ...70...
Page 222: ...11 2010...