Karel MS128 Installation & Maintenance Guide
Edition 3.2
57
For connecting KY16 to the system, the Data / Busy / GND signals on the
connection box of the system data cable (used by KAREL consoles / feature
phones as well) must be wired in parallel to the corresponding pins of the
connection box of the printer data cable (see Figure B-13).
In the absence of Karel consoles / feature phones connected to the system, the
method of cabling for KY16 may be simplified as follows :
1) The RJ plug at the end of the cable that comes from the printer must be
disconnected from the connection box.
2) This RJ plug must be then passed through passed through the hole on the
side covers of the system cabinet and then, connected to the console
socket on MS128 CPUKON card.
Figure B-13
After the installation and cabling of KY16 is completed, it is also necessary to
enter the related programming code for selecting KY16 as the CRL (Call Record
Listing) media. Refer MS128 Programming Guide.