Karel MS224 Installation & Maintenance Guide
Edition 3.2
29
Structure of the second line:
Starting
Character
Position
Field
Width
Information
1
8
Date in the format dd/mm/yy
9 1
Space
10
8
Starting time of the call in the format hh:mm:ss
18 1
Space
19
8
Ending time of the call in the format hh:mm:ss
27 1
Space
28
5
Call duration in the format mm:ss
33 1
Space
34
4
Starting extension number, OPE for the operator
and Dtt for the incoming calls coming from a
DISA line where tt is the line number.
38 1
Space
39
4
Ending extension number, OPE for the operator.
43 1
Space
44 3
Call
info
47 1
Space
48 2
Line
number
50 1
Space
51
4
Metering Pulse count
55 1
Space
56 7
Call
cost
63 1
Space
64 variable
Number
dialed
•
N
OTES
:
Only one of the PC interfaces (CM224 and / or PK224 modules) or the serial
printer can be installed to an MS224 system at a time since they use the same
serial port (PC CM socket) of the MS224 CPUKON card. The selection among
these devices is made by programming.
II.2.B. SERIAL PRINTER INTERFACE
Using the serial communication port on MS224 CPUKON card, any serial printer
can be connected to the system to have the reports of the call records and
activated system features.
The signaling between the system and the printer is illustrated in the following
table:
MS224 CPUKON Card
Printer
PC CM Socket
Pin No
Signal 25-pin
connector
Pin No
9-pin connector
Pin No
1 GND
7
5
2 TX
3 2
3 -
- -
4 CTS
20 4